Preparation – John Deere AC-350 User Manual

Page 12

Advertising
background image

1

Operator’s Manual

preparation

VeNtILAtION

WArNING: FOLLOW the MINIMUM FreSh, OUtSIDe

AIr VeNtILAtION reqUIreMeNtS. IF prOper

FreSh, OUtSIDe AIr VeNtILAtION IS NOt

prOVIDeD, CArBON MONOXIDe pOISONING

CAN OCCUr. prOVIDe prOper FreSh, OUtSIDe

AIr VeNtILAtION BeFOre rUNNING heAter.

Fresh Air Opening Requirements:

Heater Size

Square Feet Opening

350,000 Btu/Hr 10.5

Note: If you use more than one heater, provide extra fresh

air. Provide a fresh air opening of at least three square feet

for each 100,000 Btu/Hr rating.

FUeLS

WArNING: USe ONLY KerOSeNe Or #1 FUeL OIL

tO AVOID rISK OF FIre Or eXpLOSION. NeVer

USe GASOLINe, NAphthA, pAINt thINNerS,

ALCOhOL Or Other hIGhLY FLAMMABLe

FUeLS.

Do not use heavy fuels such as No.  fuel oil or No.  diesel.

Using heavy fuels will result in:

• clogged fuel filter and nozzle
• carbon build-up on spark plug
• the need of non-toxic anti-icer in fuel during very cold

weather

IMPORTANT: Use a KEROSENE ONLY storage container.

Be sure storage container is clean. Foreign matter such as

rust, dirt or water will cause flame-out control to shut down

heater. Foreign matter may also require you to clean fuel

system often.

Advertising