Operation – John Deere AC-350 User Manual

Page 14

Advertising
background image

1

Operator’s Manual

Operation

OperAtION

IMPORTANT: Review and understand the warnings in

the Safety Information section. They are needed to safely

operate this space heater. Follow all local ordinances and

codes when using this space heater.

WArNING: FOLLOW the MINIMUM FreSh,

OUtSIDe AIr VeNtILAtION

reqUIreMeNtS. IF prOper FreSh,

OUtSIDe AIr VeNtILAtION IS NOt

prOVIDeD, CArBON MONOXIDe

pOISONING CAN OCCUr. prOVIDe

prOper FreSh, OUtSIDe AIr

VeNtILAtION BeFOre rUNNING

heAter.

START SPACE HEATER:

1. Follow all ventilation and safety information.
. Locate heater to provide maximum circulation of the

heated air. Follow all location requirements noted in the

Safety Information section of this manual.

. Fill fuel tank with kerosene or #1 fuel oil.
. Attach fuel cap.
. Set thermostat dial to desired temperature.
Note: Thermostat setting must be higher than surrounding

air temperature.

6. Plug power cord of heater into three-prong, grounded

extension cord. Extension cord must be at least 6 feet

long.

WArNING: USe ONLY A three-prONG,

GrOUNDeD eXteNSION COrD. USe COrD

WIth prOper WIre SIZe tO ASSUre 120

VOLt OperAtION. (FIG. 1)

7. Plug extension cord into standard 120 volt/60 hertz,

three-hole, grounded outlet.

8. The motor will start when extension cord is plugged

into outlet. The heater should ignite at once. If heater

does not ignite, restart heater. To restart heater, wait 60

seconds, then push in flame-out control reset button.

Flame-out control reset button is at rear of heater near

power cord (Fig. ).

Note: A cold heater may affect the thermostat setting. This

thermostat is a general-heating control. It is not intended

for precise temperature control. Adjust thermostat until

heater cycles at the desired setting.

Note: If starting heater for first time, you may need to prime

the pump. If equipped, slightly open bleeder valve of pump

to allow air to escape. Quickly close valve once fuel is

seen. Wipe up any excess fuel. If equipped with canister

fuel filter, remove the canister bottom and fill with fuel.

Reassemble filter. Wipe up any excess fuel. You may also

have to do this after taking heater out of storage.

extension Cord Size requirement

Length of Cord:

Rated Cord:

Up to 100 feet (0.8 m)

1 AWG

101 to 00 feet (0.78 to 60.96 m)

1 AWG

01 to 00 feet (61.6 to 91. m)

10 AWG

01 to 00 feet (191.7 to 11.9 m)

8 AWG

01 to 00 feet (1. to 1.0 m)

6 AWG

(Fig. )

Flame-Out

Control

Reset Button

(Fig. 1)

Advertising