Connections & Installation (continued)

The following illustration shows a system in which a remote control unit (or a similar piece of equipment)
controls a single camera.

8

ACable ConnectionsB (A pg. 16)

(Terminal side of the Ceiling Mount)

8

ASwitch SettingsB (A pg. 13)

(Setting switches are on the side of the Ceiling Mount)

MEMO

● If this camera or the cables connected to this camera are used in places subject to strong electromagnetic waves or other forms of magnetism,

such as those near a radio or TV transmitter, a power transformer or an electric motor, the picture may suffer from noise and colors may be
affected.

● An optionally available controller is required to use a TK-C625 camera. Please contact your local dealer or installer for more information about

these controllers.

Point-to-Point Communication System

Controller

Control signal cable

Video out

Observe the following points when connecting components together:
●Turn all the components off before proceeding.

●Read the instruction manuals of all components before proceeding.

Switch 4 : OFF
(Point to Point)
Switch 8 : ON
(Terminated 110 K)

AC 24 V power supply
(A CAUTIONS)

Monitor

Control signal cable

Coaxial cable

Power cable

To controller

To monitor

To the AC 24V power
supply. Listed class 2
input only.
(A CAUTIONS)

Setting not
required

Switch 1 : Invalid (Set to OFF)
Switch 2 : Invalid (Set to OFF)
Switch 3 : Invalid (Set to OFF)
Switch 4 : OFF
Switch 5 : Configure in accordance

with the requirements of
the controller
communication system.

Switch 7 : Invalid (Set to OFF)
Switch 8 : ON

CAUTIONS
●The AC 24 V power supply must be isolated from the primary line. (ISOLATED POWER ONLY)
●In order to prevent an excessive current flow through the power supply wire or camera due to a short circuit, a fuse must be

installed in the power supply line.