Preparation

Operator’s Manual

11

THEORY OF OPERATION

The Fuel System: The hose / regulator assembly attaches to the Propane / L.P. gas supply. The Propane / L.P.

gas moves through the solenoid valve and out the nozzle.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air

is heated and provides a stream of clean, hot air.

The Ignition System: The direct spark ignitor (DSI) sends voltage to the spark plug/ignitor. The spark plug / ignitor

ignites the fuel and air mixture.

The Safety Control System: This system causes the heater to shut down if the flame goes out.

Air For Combustion

And Heating

Fuel

Combustion Chamber

Ignitor

Clean

Heated

Air Out

(Front)

Cool

Air In

(Back)

Fan

Motor

Power Cord

Hose/

Regulator

Assembly

Solenoid Valve

On/Off Switch

DSI

Nozzle