Installation

INSTALLATION
IMPORTANT: Review and understand the warnings in

the Safety Information section. They are needed to safely

operate this space heater. Follow all local ordinances and

codes when using this space heater.

WARNING: TEST ALL GAS PIPING AND

CONNECTIONS FOR LEAKS AFTER

INSTALLING OR SERVICING. NEVER

USE AN OPEN FLAME TO CHECK FOR

A LEAK. APPLY A MIXTURE OF LIQUID

SOAP AND WATER TO ALL JOINTS.

BUBBLES FORMING SHOW A LEAK.

CORRECT ALL LEAKS AT ONCE.

1. Provide propane supply system (see Propane Supply

section).

2. Connect POL fitting on hose / regulator assembly

to Propane / L.P. tank(s). (Fig. 1) Turn POL fitting

counterclockwise into threads on tank. Tighten firmly

using wrench. Tighten regulator with vent pointing

down.

3. Connect hose to inlet connector. Tighten firmly using a

wrench. (Fig. 2)

IMPORTANT: Extra hose or piping may be used if needed.

Install extra hose or piping between hose/regulator

assembly and Propane / L.P. tank. You must use the

regulator supplied with heater.

4. Open propane supply valve on Propane / L.P. tank(s)

slowly.

Note: If not opened slowly, excess-flow check valve on

Propane / L.P. tank will stop gas flow. If this happens,

close propane supply valve and open again slowly.

5. Check all connections for leaks.
6. Close propane supply valve.

OPERATION

WARNING: FOLLOW THE MINIMUM FRESH,

OUTSIDE AIR VENTILATION REQUIREMENTS.

IF PROPER FRESH, OUTSIDE AIR VENTILATION

IS NOT PROVIDED, CARBON MONOXIDE

POISONING CAN OCCUR. PROVIDE PROPER

FRESH, OUTSIDE AIR VENTILATION BEFORE

RUNNING HEATER.

START SPACE HEATER:

1. Follow all ventilation and safety information.
2. Place the space heater in an area that provides

maximum circulation of the heated air. Follow all location

requirements noted in the Safety Information.

3. Locate heater on stable and level surface. Make sure

strong drafts do not blow into front or rear of heater.

4. Plug power cord of heater into a three-prong, grounded

extension cord. Extension cord must be at least 6

feet (1.83 m) long, UL listed and of a proper size. See

Extension Cord Chart.

Propane

Tank

Hose

Regulator

Vent

(pointing

down)

POL

Fitting

Supply

Valve

(Fig. 1)

Hose

Inlet Connector

(Fig. 2)

Extension Cord Size Requirement

Length of Cord:

Rated Cord:

Up to 50 feet (15 m)

18 AWG

51 to 100 feet (15.5 to 30.48 m)

16 AWG

101 to 200 feet (30.78 to 60.96 m)

14 AWG

Operation