Connections

How to connect the SERIAL Terminals

SERIAL

RS-232C cable

D-sub 9p

COMPUTER

The SERIAL terminal is used when the Plasma Display Monitor is controlled by a computer.

9

8

7

6

5

3

2

1

4

Pin layout for RS-232C

Communication parameters

Notes:
(1) Use the RS-232C cable to connect the computer to the Plasma Display Monitor.
(2) The computers shown is for example purposes only.
(3) Additional equipment and cables shown are not supplied with this set.

The SERIAL terminal conforms to the RS-232C interface specification, so that the Plasma Display Monitor can be controlled
by a computer which is connected to this terminal.
The computer will require software which allows the sending and receiving of control data which satisfies the conditions
given below. Use a computer application such as a programming language to software. Refer to the documentation for the
computer application for details.

Command

Command
PON
POF
AUU
AUD
AMT
IIS

DAM

Control details

Power ON
Power OFF
Volume increase
Volume decrease
Mute (toggle)
Input select (toggle)
AV Mode
Component / RGB mode (processed as a
Y/P

B

/P

R

or RGB signals as set by this unit)

PC mode
Screen mode select (toggle)
NORMAL (4:3)
ZOOM
FULL
JUST
AUTO

Parameter
None
None
None
None
None
None
VID
YP1

RG1
None
NORM
ZOOM
FULL
JUST
SELF

Basic format for control data
The transmission of control data from the computer starts
with a STX signal, followed by the command, the
parameters, and lastly an ETX signal in that order. If there
are no parameters, then the parameter signal does not need
to be sent.

Note:

(1) If multiple commands are transmitted, be sure to wait

for the response for the first command to come from
this unit before sending the next command.

(2) If an incorrect command is sent by mistake, this unit will

send an “ER401” command back to the computer.

STX

Start
(02h)

ETX

:

C2

C1

C3

P2

P1

P3 P4 P5

Colon

Parameter(s)
(1 - 5 bytes)

End
(03h)

3-character
command (3bytes)

RS-232C Pin assignment

Pin number

2
3

5

4 • 6

7
8

1 • 9

Signal
R X D

T X D

GND

NC

Shorted

NC

Signal level

Synchronization method

Baud rate

Parity

Character length

Stop bit

X parameter

S parameter

RS-232C compliant

Asynchronous

9600 bps

None

8 bits

1 bit

None

None

18

Power ON/OFF

Connecting the plug to the Wall Outlet

Push the POWER switch on the Plasma Display Monitor
to turn the set on POWER-ON

Power Indicator: Green

Example: The screen below is displayed for a while after

the Plasma Display Monitor is turned on.
(setting condition is an example.)

When the POWER is turned on for the first time, the
LANGUAGE selection screen is displayed.

From the second time on, language selection can be
done from the setup menu. (see page 21)

Select the desired language using the and keys and
press the store

button.

From the second time on, the screen shown below is
displayed for a while (setting condition is an example).

Press the

button on the remote control to turn the

Plasma Display Monitor off

Power Indicator: Red (standby)

Press the

button on the remote control to turn the

Plasma Display Monitor on

Power Indicator: Green

To turn the power for the Plasma Display Monitor off, press
the

switch on the Plasma Display Monitor, when the

Plasma Display Monitor is on or in standby mode.

V I D E O

N O R M A L

Remote Control Sensor

INPUT

SURROUND

VOL

N

R

OSD LANGUAGE

En

g

lish (UK)

Deutsch

Fran ais

Italiano

Es

p

a ol

ENGLISH (US)

R - STANDBY

G POWER ON

INPUT

– VOL +

R - STANDBY
G POWER ON

Power Indicator

Power ON/OFF and Input Signal Selection

12

GD-

V

500PZ

U

Advertising