Installing the Projector

Please read the following carefully when installing this unit.

Minimum Space Required

Precautions for Installation

Installation Environment

Precautions for Usage

This unit is a precision device. Do not install it at
the following places. Doing so may cause fire or
malfunction of the unit.
● Where there is water, humidity or dust
● Where the unit may be subjected to oily or cigarette

smoke

● On a soft surface such as carpet or cushion
● Where the unit may be subjected to high temperature

due to direct sunlight

● When temperature is high or low

Allowable operation temperature range: +5

f to +35 f

Allowable relative humidity range: 20 % to 80 % (no
condensation)

Allowable storage temperature range:

-10 f to +60 f

● Any room in which there is cigarette smoke or grease

Even where smoke and grease levels are minimal,
prolonged exposure will affect this unit. This unit emits
heat and optical components are cooled down by taking
in a large amount of air. The optical path may be soiled
by grease/dirt, thus causing images to become dark or
color projection to deteriorate. When soiling on the
optical components occurs, removal of grease/dirt totally
will not be possible.

This unit makes use of a light source lamp that
may reach a high temperature during projection.
Do not allow projection under the following
conditions. Doing so may cause fire or
malfunction of the unit.
● Projection with the unit laid on its sides
● Projection with the unit installed in an unreasonable

angle
Avoid using this unit at an angle of more than

ؓ5 Њ

horizontally and

ؓ25 Њ vertically. Doing so may cause

unevenness in the color or shorten the lamp life.

● Projection at a location that blocks the air inlets or

exhaust vents

● Projection at a place exposed to air blasts from an air-

conditioner

Do not use a cover which may enclose this unit
or block the air inlets/exhaust vents. Allow
sufficient space around this unit. When this unit
is enclosed in a space of dimensions as
indicated on the left, use an air-conditioner so
that internal and external temperatures are the
same.

300 mm and
above

500 mm
and above

300 mm and
above

150 mm and
above

150 mm and above