46 terminal description (continued), External control command table – JVC DLA-HD10KSU/E User Manual

Page 46

Advertising
background image

46

Terminal Description (continued)

C

Parameters used for the data format

The following 3 types of parameters are used for command and response data:

(1) Numeric value (2) ON/OFF (3) Special parameters

Each parameter is as follows:

(1) Numeric value

A 2-byte hexadecimal value (sign included) is represented by a set of 4-digit (4-byte) characters.
The range that can be specified is from

A8000HB to A7FFFHB

(2) ON/OFF

Shows the status (ON or OFF) of the unit, such as POWER and HIDE.

(3) Special parameters

Operation mode parameters

c

External control command table

Operation mode: Only Asking command is possible

Character

Hex

Meaning

0

30

OFF

1

31

ON

Character

Hex

Meaning

0000

30h 30h 30h 30h

Standby mode

0001

30h 30h 30h 31h

Operate mode

0002

30h 30h 30h 32h

Cool down mode

0004

30h 30h 30h 34h

Emergency mode

Function

Command

Asking

Data Type

Operate mode

ELSE

Numeric Value

ON/OFF

Special Data

Operate

U0F

ן

ן

ן

X

ן

HIDE

U00

X

ן

ן

X

ן

Left/Right Reversal

U17

X

ן

ן

X

ן

Top/Bottom

Inversion

U18

X

ן

ן

X

ן

Operation Mode

Z03

X

X

ן

ן

X

DLA-HD10_EN-FR.book Page 46 Thursday, November 10, 2005 12:54 PM

Advertising