Preparing the Washer

Operator’s Manual



uNlOAdER

The unloader valve on your machine is equipped with an adjustment

knob to adjust the pressure. Should less pressure be required, simply

turn the adjustment knob counterclockwise. To set back to maximum, turn

adjustment knob completely clockwise. DO NOT OVERTIGHTEN!

CAuTION: RISK Of uNIT dAmAgE! dO NOT OvERTIgHTEN

THE uNlOAdER. BREAKAgE WIll RESulT IN

ImmEdIATE lOSS Of WATER PRESSuRE ANd COSTly

REPAIRS.

PRE-START INSPECTION PROCEduRES

Before starting the unit, perform the following procedures:
. Check the oil level in the pump.
. Inspect the inlet water strainer. Clean or replace if necessary. See

"Water Supply".

. Check all hose connections to ensure they are securely tightened. See

"Water Supply".

4. Inspect for system water leaks and oil leaks. Be sure that all damaged

parts are replaced and that the mechanical problems are corrected prior to

operation of the unit. If service is needed, contact Customer Service.

5. Inspect high pressure hose for kinking, cuts or leaks. If a cut or leak is

found, DO NOT USE HOSE! Replace hose before starting unit. See

"Miscellaneous Safety Precautions". Be sure that all damaged parts

are replaced and that the mechanical problems are corrected prior to

operation of the unit. If you need service, contact Customer Service.

6. Inspect electrical cord for cuts. If a cut is found, DO NOT TOUCH OR

USE ELECTRICAL CORD! Replace cord before starting the unit.

THERmAl RElIEf vAlvE

To ensure the bypass water temperature does not exceed acceptable levels,

never allow the pressure washer to operate in the bypass mode (with the unit

running and the trigger closed) for more than three minutes.
A thermal relief valve has been added to this unit to protect the pump. It may begin

to open and release water if the water temperature in the pump has exceeded

140° F. This will allow fresh, cool water to enter the system, therefore preventing

premature failure of pump packings.