Appendix F

39

IIT Camera System Manual

Besides these constants there are some commands for test purposes. These are:

Name Cmd

Syntax

Description

Disable checksum

u

#u98<CR>

Disables checksum commands until next

power down

Show input vector

O

#O<CR>

Shows the activated fiber channels. If
channel 2 and 3 are activated then the

answer will be #O06<CR>

IR Illuminator off

Z

#Z00<CR>

Switches off the IR Illuminator

IR Illuminator on

Z

#Z01<CR>

Switch on the IR Illuminator. Recycling the

power also switches the IR illuminator on.

Firmware version

V

#V<CR>

Shows the installed firmware version for

U12

Below are the settings for the microcontroller U1 on the I/O Board. This processor controls the
camera heater, fan and power supply for the camera. The settings are accessible from the EN Setup

via Serial Communication Terminal – I/O Board.

Inquiry syntax: $<command><CR>
Change value syntax: $<command><hex-value><CR>

Name Cmd

Value

Description

Hex

Dec

Power up
temperature high

Q 41 +65

The high temperature where the power
supply for the camera is switched off

Warning temperature

high

X 3F +63

The warning temperature at which the

camera will start preparing power down

Fan start
temperature

D 2D +45

The temperature above which the fan is
switched on

Fan stop
temperature

K 28 +40

The temperature below which the fan is
switched off

Camera heater off

temperature

O F6 -10

The temperature above which the camera

heater is switched off

Camera heater on
temperature

H F1 -15

The temperature below which the camera
heater is switched on

Warning temperature

low

W E4 -28

The warning temperature at which the

camera will start preparing power down

Power up
temperature low

T E2 -30

The low temperature where the power
supply for the camera is switched on