5

Connect the camera to

the Ethernet port of an
appropriate test PC.

Switch on the camera
power. Launch EN Setup

application

Sec. 4

6

Align camera

mechanically to correct
position by adjusting

the VIS Mount and using
the tools from EN

Setup.

Do not adjust

the camera mount

inside the housing.

Sec. 4

7

Focus lens and make
sure that the lens iris is

fully open and no
polarizer is mounted.

Secure locking screws
after adjustment

Appendix B

8

Properties settings using
internal Light Sensor:


Sec. 4.1

(IIT IO Board settings: X=05, Y=0A, M=C8, K=01, P=3A, Q=03, T=96)

Properties settings using
external Light Sensor:




Sec 4.2

(IIT IO Board settings: X=05, Y=0A, M=C8, A=10)