Appendix F

Besides these constants there are some commands for test purposes. These are:

Name Cmd

Syntax

Description

Disable checksum

U

$u99<CR>

Disables checksum commands until next
power down

Firmware version

V

$V<CR>

Shows the installed firmware version for U1

Status request

S

$S<CR>

The format of the answer is
$S<temperature><temperature status><fan

stauts><heater status><CR>

The temperature is shown in two’s
complement.


Example of an answer:
$S1A800<CR>

“1A” is 26 deg
“8” is power ok

“0” fan off, no current, no overload
“0” heater off, no current, no overload

Heater and fan status:
0: off, no current, no overload (ok)

1: on, no current, no overload (fault)
2: off, no current, no overload (fault)

3: on, no current, no overload (ok)
4: off, no current, no overload (fault)

5: on, no current, no overload (fault)
6: off, current, overload (fault)

7: on, current, overload (fault)