Hydrostatic Drive Operation-

60 and 90 Loaders-Continued

0

0

PUMP

~

FILTER

CSM949

Each pump is connected by hose routing to a hydrostatic

gear motor. Hydraulic fluid is drawn by the pumps from the

reservoir through a filter. The pumps then deliver the pres-

surized fluid to the motors.

REAR PRIVE SPROCKET

\

"'"

FRONT DRIVE SPROCKET

(90 Skid-Steer Loader shown)

Sprockets on the output shaft of each motor are connect-

ed to each axle drive sprocket by a one-step drive chain, in

order-to obtain four-wheel drive.

CSM950

Aug. 84 Utho in U.S.A.

(60 Skid-Steer Loader shown)

The motors and chains of the 60 Skid-Steer

Loader are

located under the floor panel, in the 18-U.s.-gallon reservoir,
for cooling and lubrication.

(90 Skid-Steer Loader shown)

On the 90 Skid-Steer Loader, the ratio between engine

horsepower, hydrostatic motor size and reservoir size is such

that the motors have sufficient coolingwithout being placed
in the hydraulic reservoir.The chains are located in 1.5-U.S.-
gallon chain cases for lubrication ("A" above).

The 90 Loader features a T-bar, and the 60 Loader uses

two levers to control the direction and ground speed of the

loader. Two-lever control is necessary on the 60, in order to
allow easy entry and exit of its narrow operator station.

A neutral start safety switch is provided at the base of the

drive clutch lever. This means that the pumps must be dis-
engaged before the engine will crank.