How to use the external control, About the external control, How to use the make/trigger terminal – JVC TM-15L1D User Manual

Page 18

Advertising
background image

18

How to Use the External Control

7

About the external control

The monitor has the MAKE/TRIGGER terminal, which allows you to control the monitor by the MAKE (make contact)
or TRIG. (trigger) system.

MAKE (make contact) system: Controls the function by short-circuiting the corresponding pin terminal to the

GND pin terminal, or disconnecting (opening) it.

TRIG. (trigger) system:

Controls the function by inputting the pulse signal instantaneously to the
corresponding pin terminal.

* Select “MAKE” or “TRIG.” from “SYSTEM” in the “REMOTE SETTING.”

☞ “REMOTE SETTING” on page 16

NOTE:
• When using the make contact system, you cannot use the buttons on the front panel to utilize functions which are controlled

through the MAKE/TRIGGER terminal. (When using the trigger system, you can also use those functions using the buttons on
the front panel or the menu.)

• When using the make contact system, you cannot change the inputs using the buttons on the front panel.

7

How to use the MAKE/TRIGGER terminal

No.

Functions to be controlled

Opening

Short-circuiting

*1

1

Controls the tally lamp

Off

On

*2

2

Changes color of the tally lamp

GREEN

RED

3

Changes the input to the one assigned
to “PORT F3” in “REMOTE SETTING”
(

☞ page 16)

Invalid

Valid

4

Changes the input to the one assigned
to “PORT F4” in “REMOTE SETTING”
(

☞ page 16)

Invalid

Valid

5

Turns on/off COLOR OFF function

Off

On

6

Changes ASPECT to 16:9

Off

On

7

External control

Invalid

Valid

*3

8

GND

*1 The TRIG. (trigger) system switches each function by short-circuiting for approx. 1 second.
*2 Tally lamp (the 1st pin terminal) must be controlled by the MAKE (make contact) system. You can control the tally

lamp even when the external control (the 7th pin terminal) is invalid.

*3 External control (the 7th pin terminal) must be controlled by the MAKE (make contact) system.

Operation
1. Short-circuit the 7th pin terminal (External control) to the 8th pin terminal (GND) so that the monitor can be

controlled externally.

2. When selecting the “MAKE” (make contact) system, operate each function by short-circuiting the

corresponding pin terminal to the 8th pin terminal (GND) or opening it.
When selecting the “TRIG.” (trigger) system, operate each function by pulse control, that is short-circuiting the
corresponding pin terminal to the 8th pin terminal (GND) for about 1 second.

NOTE:
• When controlling No. 3 and 4 pin terminals by the MAKE (make contact) system, only the terminal in use must be short-

circuited. (Another terminal must be opened.)

• When selecting the “TRIG.” (trigger) system, you can operate only one function at a time. Operate the functions one by one.

This is a female
terminal.

03_TM-15L1D-EN2.indd 18

03_TM-15L1D-EN2.indd 18

06.11.15 1:07:40 PM

06.11.15 1:07:40 PM

Advertising