Installing pipework – John Mills Speedfit KM39767 User Manual

Page 10

Advertising
background image

The Speedfit range includes a Double Check Valve
(Part No 15DCV) to enable installers to comply with Water

Regulation Schedule 2.15,
thus preventing contamination
o f

w a t e r

a r i s i n g

f r o m

back siphonage, backflow or
cross connection.

Washer

Hole dia.

15mm pipe

29mm

22mm pipe

36mm

28mm pipe

46mm

Cold water tank

The minimum distance to make a solder connection on
copper pipe inserted into a Speedfit Fitting is 450mm
(18 inches). Ensure that any residual flux solder is not
allowed to come in contact with the fitting. That same
measurement is the safe distance to use a freezer kit to
Speedfit Pipe.

Care should be taken when designing and installing a
central heating system where radiators are supplied by
pipe work which drops from an upper floor.

With this kind of system it is possible to trap air in the
upper floor pipe work. When the boiler is fired the increase
in pressure within the pipe caused by expanding air could
cause the pipe to burst.

It is therefore essential that the system be designed so
that any air can be removed from the system either
automatically or manually by installing automatic or
manual air vents at the highest points of the system.

Speedfit pipe should not be used to provide the discharge
from unvented cylinders, unvented water heaters and sealed
systems via the temperature relief and pressure relief values.

Speedfit recommend that mains supply pipework to unvented
water heaters (up to 15ltr capacity), be run in metal pipes.

Speedfit pipe should be connected to circulating pumps,
motorised valves in accordance with the section in this
book headed, “Connecting Plastic Pipe To Compression
Fittings”. If Speedfit pipe is not mounted on a supporting
structure, the pipe must be clipped close to the components’
connections to ensure adequate support and to assist in
the reduction of vibration.

For heavier equipment, ensure that appropriate metal
brackets provide full and independent support of the
components and that it does not rely solely on the pipework
for support.

To install the Speedfit Tank Connector, unscrew the nut
and push the body of the fitting through the tank hole with
the washer on the inside of the tank.

Hand tighten the nut onto the body. Push the pipe into
the connector.

Note: Hand tightening the nut onto the body is all that is
required. Further mechanical tightening will damage the fitting.

Maximum wall thickness of tank 4mm

IEE Guidance Note 7 provides useful guidance on the
design of electrical installations where there is increased
risk of electric shock. It recognises that the requirement
for supplementry bonding may be relaxed where metal
taps and plastic pipes supply other bathroom fittings.

Similarly a metal bath or radiator not connected to an
extraneous-conductive-part is not required to be connected
to the local supplementry conductors.

Metal

Pipe

Metal

Pipe

Speedfit Pipe and Fitting

Clip

Clip

Earth Lead

The most common way of running pipework to a radiator
is to run both flow and return pipes central to the
radiator position.

Once the plasterboard is installed the pipes are passed
through the Speedfit Radiator Outlet Plate to exit
plasterboard without the need of unsightly holes.

Metal reducing sets which convert radiator valves from
15mm to 10mm are not suitable for use with Speedfit
Fittings or Pipe as they can cause damage to the plastic.

Pipe

Supplementary Bond Comments

Material

Required Between

Earth terminals of

protective conductors of

class I and of class II

equipment and accessible

exposed conductive parts

of the building structure.

Hot water pipe, central

heating pipes, earth

terminals of protective

conductors of class I and

class II equipment and

accessible exposed

conductive parts of the

building structure.

Central heating pipes, the

earth terminals of

protective conductors of

class I and class II

equipment and access to

exposed conductive parts

of the building structure.

All metal pipes,

earth terminals of

protective conductors

class I and class II

equipment, and accessible

exposed conductive parts

of the building structure.

All metal pipes,

earth terminals of

protective conductors of

class I and class II

equipment, and accessible

exposed conductive parts

of the building structure.

Bonding of metal taps

metal radiatorsor metal

baths is not required

unless the bath is

connected to the

metallic building structure.

A bond is not required

to the taps either hot

nor cold, or to metal

baths unless connected

to the metallic

building structure.

Bonding of metal water

taps is not required,

nor metal baths unless

connected to the metallic

building structure.

Metal pipes themselves

can be used as bonding

conductors if joints are

metal to metal and

electrically continuous.

Metal central heating

radiator does not

require bonding.

Cold

Hot Central

Water Water Heating

P

P

P

P

M

M

P

P

M

M

M

M

M

M

P

P = Plastic M = Metal NB: All Waste Pipes are plastic.
1. Supplementary bonding is carried out to the earth terminal

of protective conductors of class I and class II equipment
within the bathroom. A supplementary bond is not run
back to the main earth.

2. Metal window frames are not required to be supplementary

bonded unless they are electrically connected to the
metallic structure of the bonding.

3. Metal baths supplied by metal pipes do not require

supplementary bonding if all the pipes are bonded and
there is no other connection of the bath to earth.

4. All bonding connections must be accessible and labelled

“Safety Electrical Connection - Do Not Remove”.

DROP-PIPE SYSTEMS

DISCHARGE PIPES

WATER HEATERS

CONNECTION TO PUMPS AND VALVES

CONNECTION TO COPPER PIPE

CONNECTING TO COLD WATER STORAGE TANK

PREVENTING BACK FLOW

RADIATOR CONNECTIONS

ELECTRICAL CONTINUITY CONT’D

SUPPLEMENTRY BONDING TO BATHROOMS

INSTALLING PIPEWORK

Speedfit Barrier Pipe is manufactured to BS 7291 Parts 1,
2 and 3 Class S and is Kitemarked.

The pipe is available in coils and straight lengths. See
pages 14. Pipe markings are spaced to aid the making of
a good connection when using a Superseal Pipe Insert.

15mm B-PEX to BS7291 : Part 3 : 1990 Class S 12 BAR 20°C - 4 BAR 82°C - 3 BAR 92°C

It is made up of 5 layers, the
centre of which is a blue
coloured oxygen barrier
which prevents the ingress
of air into the system, thereby
reducing the effect of corrosion
on metal components.

Because of it’s low thermal conductivity, when carrying
hot water, Speedfit Pipe is cooler and therefore safer to
touch. Relatively low heat loss through radiation means that
a system retains it’s heat longer and delivers hot water
more quickly and with less wastage than a metal system.

SPEEDFIT BARRIER PIPE

For general guidance on pipework sizing, please refer to
BS6700 or the Institute of Plumbing Engineering Services
Design Guide. Speedfit fittings are suitable for pipes
within ±0.1mm of nominal size. They can be used with
copper pipe to BS EN 1057 or Speedfit plastic pipe.

The Product Range List shows the fittings available for
reducing pipe diameters within the system.

Speedfit pipe is available in straight lengths and coils.

Pipe Diameter

Straights

2m

-

15mm

22mm

-

3m

-

15mm

22mm 28mm

6m

-

15mm

22mm 28mm

Coils

25m 10mm

15mm

22mm

-

50m 10mm

15mm

22mm

-

100m 10mm

15mm

-

-

120m

-

15mm

-

-

150m

-

15mm

-

-

PIPEWORK SIZING

17

18

22mm Barrier-PB to BS7291-2 2001 Class S 12 BAR 20°C - 4 BAR 82°C - 3 BAR 92°C

The pipes exit a single
gang box (fitted with rubber
grommets) located at the
mid height of the finished
radiator position. This also
provides a fixed point for
other trades to work to and
reduces the risk of damage
to the pipework.

Unvented pressurised cylinders can be installed using
Speedfit Pipe and Fittings. However, insertion depths on
compression joints that form part of the cylinder must be
checked prior to installation and the use of standard pipe
inserts (Prefix TSM) is recommended.

In accordance with current U.K. Building Regulations
(Part G), discharge pipes from temperature and/or pressure
relief valves must be run in metal pipework.

Speedfit connections to combined Cylinder/Boiler
units and Thermal Storage Units must be made outside
the casing unless otherwise stated in manufacturers
installation literature.

CONNECTION TO CYLINDER & WATER
HEATERS CONTINUED

The plumbing or heating system installer should have
these aspects checked to ensure compliance with current
IEE regulations. If in doubt please contact the Speedfit
Technical Advisory Service or your local Electricity Authority.

ELECTRICAL CONTINUITY

UNVENTED PRESSURISED CYLINDERS

Unvented Pressurised Cylinders can be installed using
Speedfit pipe and fittings. However if the safety
parameters of the cylinder exceed those of the pipe and
fittings it is possible to fit a pressure reduction valve on
the out going hot supply pipe. This will not interfere with
any other cylinder safety devices demanded by
regulations as they are all fitted in the incoming side of the
cylinder. Run a short length of copper pipe from the
cylinder connection (about 150mm - 300mm) then fit a
Honeywell DO5F pressure reduction valve. This will
protect the pipe and fittings from excessive pressure in
the event of boiler / cylinder malfunction. The factory
fitted temperature / pressure relief valve on the cylinder
will discharge below 100˚C therefore protecting the pipe
from excessive temperature.

JG Speedfit aluminium foil tape can be used to fulfil the
NHBC requirements for the identification of location of
plastic pipes in or behind a wall surface by a metal
detector. It features a bright aluminium finish, rubber/resin
high-tack adhesive and quality siliconised backing paper
to allow the easy handling of short, cut lengths.

D

DO

O N

NO

OT

T s

sttiic

ck

k tth

he

e tta

ap

pe

e tto

o tth

he

e S

Sp

pe

ee

ed

dffiitt p

piip

pe

e o

orr ffiittttiin

ng

gs

s

o

orr tth

ho

os

se

e o

off a

an

ny

y o

otth

he

err m

ma

an

nu

uffa

ac

cttu

urre

err..