Installation time reduced by up to 40%

Pipe flexibility permits the cabling of pipe through less
accessible areas

No risk of fire or flames from a blowtorch

Easier to work in confined places

A permanent leak-proof connection

Corrosion free

No scale build up

Lower thermal diffusivity maintains safer surface
temperature

Pipe elasticity can reduce the possibility of bursting
under freezing conditions

Lead free and non toxic

Less noise from water flow and expansion/contraction

Long pipe lengths reduce fittings required

SYSTEM FEATURES

All white system

Truly demountable without damage to pipe or fitting

Grip and seal connection

Superseal Insert gives secondary seal

Reduced pipe insertion force

Lightweight and easy to handle on site

SYSTEM BENEFITS

As a result of long term test programmes and rigorous
quality standards, John Guest Speedfit Limited offer a 25
year guarantee against the defects in materials or
manufacturing of ‘PEM’, ‘PSE’ and ‘SFM’ Range
Plumbing

Fittings

and

Speedfit

Barrier

Pipe

manufactured by John Guest.

John Guest Underfloor Heating Products, which should
be installed and maintained in accordance with our
recommendations, carry a 2 year guarantee against
defects in materials and manufacture.

John Guest Plumbing and Heating Products are for use
with normal UK domestic plumbing and heating systems
and supplied in accordance with our Conditions of Sale.

GUARANTEE

Boats. The flexibility of the Speedfit System ensures it can
be cabled easily around the interior and hidden from view.

Caravans. Speedfit is ideal for caravan installations due
to its flexibility and its resistance to corrosion and freezing.

Exhibitions. The unique ability of the Speedfit System to
be easily demounted and reused, together with its
flexibility, makes Speedfit ideal for this application.

Agricultural and Horticultural.

Speedfit

has

many

applications in agricultural and horticultural environments.

Portable Buildings (site cabins, toilets). As with caravans,
Speedfit is well suited to this application.

Speedfit fittings suitable for central heating systems can
withstand temperatures up to 114°C intermittently for
short periods.

Speedfit fittings shown as not suitable for central heating
systems are used primarily on the domestic hot and cold
water system accepting temperatures of up to 65°C.

Ensure fittings and pipe are kept clean at all times by
keeping them in bags and boxes provided.

Do not empty Speedfit Products onto the floor area.

Ensure internal ‘O’ Ring seals are kept free from dirt and debris.

John Guest fittings and related products are specifically
designed and manufactured by John Guest to the
Technical Specifications set out in the John Guest
Product Catalogues. All John Guest fittings and related
products should be selected, installed, used and
maintained in accordance with these Technical
Specifications. It is the customer’s / user’s responsibility
to ensure that John Guest fittings and related products
are suitable for their intended applications, are properly
installed and maintained and are used in accordance with
the Technical Specifications. It is also the customer’s /
user’s responsibility to provide it’s own customers with
any relevant technical information about John Guest
products it supplies them.

Speedfit should not be used for gas, fuel oil or compressed
air applications.

John Guest produce a push fit system of pipe and fittings for
compressed air situations. See seperate literature for details.

SPECIAL APPLICATIONS

WORKING TEMPERATURES AND PRESSURES

HANDLING FITTINGS AND PIPE

PRODUCT SELECTION AND INSTALLATION

03

04

Contents

PLUMBING AND HEATING

UNDERFLOOR HEATING

UNDERGROUND FITTINGS

TECHNICAL CHECKLISTS

Plumbing and

09 - 10

Heating Fittings

Flexi Hoses

11 - 12

Brass Fittings

12

Valves

13

Pipe and

14 - 15

Accessories

22 - 26

27 - 28

Designed to be quick and easy to install.

For connecting MDPE
Cold Water Service Pipe.

Plumbing and Heating

29

Underfloor Heating

30

Underground Fittings

30

Application

Usual Working

Maximum working

Maximum working

temperature, ºC

temperature, ºC

pressure, bar

Cold Water

20

20

12

(indirect and direct mains)

Central Heating

82

105, short term

3

malfunction at 114

Hot Water

65

95

6

(including unvented cylinders)