JVC TK-C215V4 User Manual

Page 10

Advertising
background image

18

Installation and connection (continued)

Embedding the camera to the ceiling

* Make use of a ceiling material with a thickness

between 9.5 mm to 22 mm.

Setup

1.

Open a hole in the ceiling. (

R120 mm)

2.

Draw the fall prevention wire mounted to
the ceiling slab and the cable out from the
ceiling in advance.

CAUTION:

● Select a suitable safety cable based on

length, strength, location, material
(insulation property), etc.

● Use a ring on the fall prevention wire for

mounting to the camera unit with an
internal diameter of at least

R3.1 mm or and

not larger than

R5.5 mm, and an external

diameter that is not larger than

R9 mm.

3.

Remove the dome cover.
As illustrated in the diagram, hold the dome
ring such that the position mark comes
between the thumb and index finger. Turn the
ring in the anti-clockwise direction to remove.

4.

Remove the outer case.
(This method does not require an outer case.)

A

Loosen the outer case fastening screw with a
screwdriver

B

To remove, turn the camera unit in the anti-
clockwise direction

5.

Dismantle the supplied fall prevention wire
Unfasten the mounting screw for the fall
prevention wire at the rear of the camera unit

6.

Loosen the pan fastening screw.

CAUTION:

Moving the lens unit without loosening the pan
fastening screw may damage the lens unit.

7.

Set the switches for video images.
(TK-C215V4

A pg. 10)

(TK-C215V12

A pg. 12)

(TK-C210FW

A pg. 14)

Mounting the Camera to the
Ceiling (continued)

1.

2.

R120 mm

Approx. 100 mm

Video signal cable

Power supply cable

Alarm signal cable

*TK-C215V12 only

Fall prevention

wire

(not supplied)

3.

Dome Ring

Position mark

B

A

4.

7.

5.

4.

Camera
Fastening Screw

*TK-C215V4 is used in the above illustration

Pan fastening
Screw

Washer

19

Connecting

1.

Attach the fall prevention wire to the
camera, followed by attaching it to the
ceiling slab (Fall prevention wire is not
included.)

2.

Connect the video signal cable. (

A pg. 14)

Lower the cover and connect the connectors.
Upon connecting, cover the connectors using
the protection cover.

3.

Connect the input power supply cable.
(

A pg. 15)

4.

Install the Ferrite core (TK-C210FW only)
(

A pg. 14)

5.

Connect the alarm cable. (TK-C215V12 only)
(

A pg. 15)

6.

Wrap insulation tape around cables.

7.

Insert the camera unit into the ceiling hole.

Mounting

1.

Align

j with the shooting direction when

mounting the camera.

2.

Fasten the camera. (x3 locations)

A

Press the screw head of the clamping bracket
all the way in using a cross screwdriver.

B

With the screw pressed in using the
screwdriver, turn about 90

Њ in the clockwise

direction, followed by pulling out the
screwdriver.

C

The clamping bracket is attached to the ceiling
and the camera fastened.

NOTE:

Dismantle the camera upon turning the screw
heads of the ceiling mount bracket (x3) by 90

Њ

in the anti-clockwise direction.

Adjusting Images

After mounting is completed, adjust the
images while checking the actual image.
(

A pg. 23

AAdjusting ImagesB)

1.

7.

2.

6.

3.5.

Protection

cover

*TK-C215V12 is used in the above illustration

Alarm signal cable
(TK-C215V12 only)

Solder or crimp

Insulation tape

Wrap with tape

Input power
supply cable

Fall preven-

tion wire

(not supplied)

FRON

T

UP

B

A

1.

2.

Align with shooting direction

*TK-C215V4 is used in the above illustration

Advertising