26

Adjusting Image (continued)

‹ Registering alarm position

For registering the angle of view during
monitoring when there is an alarm input.

1.

Check that the [ALARM POSITION]
indicator light is turned on.
Registration of alarm position is enabled.

● Press the [POSITION SELECT] button if the

[ALARM POSITION] indicator light is off.

2.

Adjust the image size. (

A pg. 25)

3.

Press the [MEMORY] button for 2 seconds
or longer.
The [ALARM POSITION] indicator light blinks
for 3 times (green)

ALARM position registration is completed

4.

Adjust the brightness. (

A pg. 25)

5.

Press the [POSITION SELECT] button.
The camera returns to the home position

NOTE:

● Be sure to return the camera to the home

position after registration of the alarm position
is completed.
In addition to pressing the [POSITION
SELECT] button, you can also use the power
ON/OFF button to return the camera to the
home position.

● To check images at the registered home

position or alarm position, press the
[POSITION SELECT] button. Press this
button to switch between the image at the
home and alarm positions.

After setting is complete, mount the dome cover.

1.

Mount the dome cover.
Align the position marks on the camera unit
and dome cover, followed by pressing in
directly to mount the cover.

CAUTION:

Press the dome over until a “click” sound is
heard. Check that the cover is firmly mounted.
Failure to mount the cover firmly may cause
this cover to fall off.

Adjusting Images
(continued)

Ň

B

RESET/[SPOT]

LL

PHASE

R

WHT.BAL.

H

L

IRIS

LEVEL

ZOOM/FOCUS FAR

WIDE

NEAR

POSITION SELECT

POSITION

ALARM

[MEMORY]

2

4

1

2

3

4

5

6

7

8

TELE

4.

1.,5.

2.,3.

Mounting the Dome Cover

1.

Position mark

27

As a general characteristic unique to CCDs,
white-spots may appear on the screen with age.
In order to reduce this phenomenon, this unit is
equipped with a white-spot correction feature.
Switch on the camera power supply and wait for
at least 30 minutes.
(Not available on TK-C210FW)

‹ TK-C215V4

‹ TK-C215V12

1.

Remove the dome cover.

2.

Cover the lens surface using a black sheet
of paper, etc. so that light does not enter the
lens.

3.

Set the function selection switch 8 to
[SPOT]. (

A pg. 11, 13)

4.

Press and hold the SPOT CORRECTION
button for more than 2 seconds.

● White-spot correction will start. Correction

may take several seconds for completion.

NOTE:

● Maximum correction: less than 16 to 32

spots

● The white-spot correction feature of this

unit does not guarantee the correction of
all white spots.
Depending on the characteristic of white
spots, correction may not be possible.

● When performing white-spot correction,

accurate data may not be achieved in case
of highly detailed pixels since correction is
made using the information of surrounding
pixels.

● The result of white-spot correction is

maintained until the next correction is
performed.

White-spot correction

RESET/[SPOT]

LL PHASE

1

O

N

2

3

4

5

6

7

2
4

WHT.

BAL.

8

B

R

Function selection switch 8

[SPOT] button

B

RESET/[SPOT]

LL

PHASE

R

WHT.BAL.

H

L

IRIS

LEVEL

ZOOM/FOCUS FAR

WIDE

NEAR

POSITION SELECT

POSITION

ALARM

[MEMORY]

2

4

1

2

3

4

5

6

7

8

TELE

Function selection
switch 8

[SPOT] button

Advertising