The exhaust system must be sized to handle this volume for the dishmachine to operate as it was designed to.

ELECTRIC HEAT: The thermostats for the machines covered in this manual are factory set. They should not be adjusted except
by an authorized service agent.

CHEMICAL FEEDER EQUIPMENT: The AJ-44CEL/CSL, AJ-66CEL/CSL, and AJ-80CEL/CSL are designed to operate with a
third party chemical injection system. Jackson does not endorse any particular chemical injection system. The system select-
ed must be able to provide detergent and sanitizer in the required concentrations. The minimum chlorine concentration for prop-
er sanitization is 50 PPM. Furthermore, the selected feeder needs to be able to operate against a head of 25 PSI and deliver
7.38 ml of a 10% chlorine sanitizer per minute.

Detergent may be introduced into the unit through the removal of the
bulkhead plug in the rear of the tub and replacing it with the third
party detergent injection fitting. Remove the bulkhead plug in the
side of the tub to install the detergent concentration probe.

For more information concerning detergent concerns, please refer to

the page entitled “Detergent Control”.

The 1/8” brass plugs on the incoming plumbing rinse injector may be removed to install
sanitizer and rinse aid injection fittings.

All wires for the chemical injectors should be routed

through one

of the extra openings in the back of the control box.

Terminals in the control box marked “CVS” provide a constant voltage signal whenever the
drive motor is operating.

Terminals in the control box marked “DET” provide a voltage signal whenever the wash motor
is operating.

AJ-44C Series Technical Manual 7610-001-76-22

Issued: 03-21-2006 Revised: N/A

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS (CONTINUED)

32

Aid Connection Points

Back of Control Box

Detergent Connection Point

(Machine rear view)

Brass Plug

Brass Plugs