Heating cartridge check (at contactor) – Southbend STRE-3EZ User Manual

Page 24

Advertising
background image

S

ERVICE

S

TRATO

S

TEAM

C

OUNTERTOP

S

TEAMER

P

AGE

24

OF

44 O

WNER

S

M

ANUAL

1185184

Figure 12

Heating Cartridge Check (at Contactor)

L1

A

L2

B

L3

C

Top of

Steamer

Ohms

1. DISCONNECT POWER AT CIRCUIT BREAKER.

2. Turn Control Lever to OFF.

3. Remove right side panel of steamer.

4. DO NOT DISCONNECT HEATING-CARTRIDGE LEAD WIRES FOR THIS TEST.

5. Using a multimeter, check the resistance across contactor terminals as specified in the following table:

Serial-

Plate

Voltage

Model STRE-3EZ

Model STRE-5EZ

Allowable Resistance (Ohms)

Allowable Resistance (Ohms)

Three-Phase

Single-Phase Three-Phase

Single-Phase

A-B and B-C

A-C

A-C

A-B and B-C

A-C

A-C

208

10 to 12

14 to 16

5 to 6

8 to 10

11 to 13

4 to 5

220

12 to 13

15 to 18

6 to 7

9 to 11

13 to 15

5 to 6

240

14 to 16

18 to 21

7 to 9

11 to 13

15 to 17

6 to 7

6. If the measured resistance at the contactor is not in the specified range, disconnect all the heating cartridges

from the contactor. Measure the resistance across the leads each cartridge. Replace any cartridge that
shows either an open or short circuit.

Advertising