Southbend STRE-3EZ User Manual

Page 8

Advertising
background image

O

PERATION

S

TRATO

S

TEAM

C

OUNTERTOP

S

TEAMER

P

AGE

8

OF

44 O

WNER

S

M

ANUAL

1185184

S

HUTDOWN

Turn lever to the “OFF” position. The water in the bottom of the cavity will automatically drain.

T

ROUBLESHOOTING BY

O

PERATOR

The following table lists the possible causes and solutions of problems that may occur during operation.

Problem

Possible Causes and Solutions

Steamer does not heat up at all.

– Electric power is shut off. Turn on power.

– Not enough water is in steamer. Add water.
– Lime build-up. De-lime steamer cavity (see page 11).

– If water is OK and there is little lime build-up, call repair service.

Steamer does heat up, but does not produce enough steam.

– Door is open or ajar. Close steamer door completely.
– Lime build-up. De-lime steamer cavity (see page 11).

– Not enough water. Add water.

Steamer does not drain correctly.

– Clogged drain on inside of steamer cavity. Check and clear.

– Clogged drain outside of steamer. Check and clear.

Advertising