Chapter 3
Configuring Driver Parameters
27
▼
To Set Driver Parameters Using a
ixge.conf
File
1. Obtain the hardware path names for the
ixge
devices in the device tree.
a. Check the
/etc/driver_aliases
file to identify the name associated with a
particular device:
Note –
ixge
"pci8086,1048.108e.7036" is used by the Sun 10-Gigabit Ethernet
adapter.
b. Locate the path names and the associated instance numbers in the
/etc/path_to_inst
file.
# grep ixge /etc/driver_aliases
ixge "pci8086,1048.108e.7036"
# grep ixge /etc/path_to_inst
"/pci@9,600000/ethernet@1" 0 "ixge"
                                    Advertising
                    
                        
                    
                            
            
            
                            
                    See also other documents in the category Sun Microsystems Hardware:
                    
                        
                
            
        - 6.0005E+11 (333 pages)
 - SOLARIS 10 (121 pages)
 - Sun Adapter TCP (150 pages)
 - Sun Fire X4150 (150 pages)
 - Sun StorageTek 5800 (136 pages)
 - Virtual Tape Library (292 pages)
 - eWay JDBC/ODBC Adapter (133 pages)
 - LSI22320-SR (48 pages)
 - Ethernet MMF/UTP Adapter (122 pages)
 - SunSwift 600MP series (28 pages)
 - 2.0 (60 pages)
 - FASTETHERNET 6U (106 pages)
 - Netra CP2500 (74 pages)
 - 1.0 (182 pages)
 - GigaSwift Ethernet Adapter (126 pages)
 - SUN BLADE 150 (20 pages)
 - X1150A (106 pages)
 - Sun Quad (62 pages)
 - VIRTUALBOX VERSION 3.1.0_BETA2 (283 pages)
 - Sun StorageTek SG-XPCIE2FCGBE-E-Z (54 pages)
 - SG-XPCIE2FC-EM8-Z (56 pages)
 - STOREDGE A5000 (2 pages)
 - THE SUN 805-7945-10 (24 pages)
 - Sun FastEthernet PCI Adapter 805-1759-10 (38 pages)
 - Sun Fire X4150 Server (80 pages)
 - 805-1797-10 (65 pages)
 - Sun StorEdge 5210 NAS (100 pages)
 - Sun StorEdge A5000 (2 pages)
 - StorEdge 3900 Series (162 pages)
 - Sun PCI High Speed Quad Port Serial Interface Adapter 819-1207-11 (64 pages)
 - Sun Fire X4200 M2 (50 pages)
 - StreamLine SL8500 (200 pages)
 - Sun StorEdge T3 (88 pages)
 - TIMBERWOLF 9740 (100 pages)
 - eWay SAP BAPI (123 pages)
 - Ethernet PCI Adapter (10 pages)
 - StorageTek L40 (92 pages)
 - Smart Cards (14 pages)
 - SUN STORAGETEK VSM GUI (68 pages)
 - Gigabit Ethernet MMF/UTP Adapter (122 pages)
 - Sun Fire X4100 M2 (50 pages)
 - PCI (50 pages)
 - StorageTek HP LTO4 (38 pages)
 - Netra CP32x0 (66 pages)