To check link partner settings – Sun Microsystems Ethernet PCI-X Adapter User Manual
Page 48

32
Sun 10-Gigabit Ethernet PCI-X Adapter Installation and User’s Guide • December 2005
▼
To Check Link Partner Settings
Type the
kstat
command as superuser:
xcvr_id
GMII/MII physical layer device Identification Decimal copy of
MII registers 2 and 3.
xcvr_inits
Number of physical layer re-initializations incremented each time
link parameters are changed using NDD.
xcvr_inuse
Type of Transceiver/SERDES which is always PCS (3).
CODE EXAMPLE 3-1
Output from
kstat
Command
# kstat ixge:1
module: ixge instance: 1
name: ixge1 class: net
brdcstrcv 0
brdcstxmt 0
cap_1000fdx 0
cap_1000hdx 0
cap_100fdx 0
cap_100hdx 0
cap_100T4 0
cap_10fdx 0
cap_10gfdx 1
cap_10ghdx 0
cap_10hdx 0
cap_asmpause 0
cap_autoneg 0
cap_pause 0
crc_err 0
crtime 147.15892392
ierrors 2
ifspeed 10000000000
ipackets 0
ipackets64 0
lb_mode 0
link_asmpause 0
link_duplex 2
link_pause 0
link_speed 10000
link_T4 0
link_up 1
local_faults 1
mac_mtu 0
TABLE 3-6
Receive and Transmit Parameters
Parameter
Description