5.4.4.4 Event Max PPS

Event Max PPS is used to set the event recording rate for Event status.
Normally, the Event PPS is set to be equal to or greater than Normal PPS; the
setting depends on your application. If the Event PPS is set to <0>, the

DVR-4TN/8TN/16TN/16TS/16TT

series unit stops recording event video

during alarms.

5.4.4.5 Event Qlty

This item is used to set the picture size for event status recording. Refer to
Section 5.4.4.3 for the available options.

5.4.4.6 Event Active

Users are allowed to choose which alarm type needs to be recorded. The
available options are <Alarm> (alarm events), <Motion> (motion detection
events), <Both> (alarm event + motion detection), and <None> (no events
active). The default setting is <Both>, which includes Alarm and Motion event
recording.

5.4.5 ezRecord

Setup

This item aims to avoid the complicated record settings and to make the setup
much easier. Note that this item can be reached only when you select
<ezRecord> as the option for <Preset Config>. For more information, please
refer to the

Appendix J: ezRecord Diagram Sample

.

Select <ezRecord Setup> from <Record Setup> and press ENTER, the
sub-menu appears as shown below:

ezRecord Setup

How Many Days To Record
Daytime Record
Night Record
Weekend Record
Overall Recording Condition

1 Days

Yes
Yes
Yes

Best