SUPER MICRO Computer AS1020S-8 User Manual

Page 56

Advertising
background image

5-22

AS1020S-8 User's Manual

Reading the POST Code LEDs:

When on, each of the eight separate LEDs

represent the value of the number shown

beside it in the diagram on the left. Add up

the numerical values of each illuminated

LED in the DB5-DB8 column to get the high

(left) digit and those in the DB1-DB4 column

to get the low (right) digit of the correspond-

ing POST code.

Example:

The example on the left indicates a hexa-

decimal POST code of C6. This is deter-

mined in the following manner:

DB1-DB4 (low digit): 4 + 2 = 6

DB5-DB8 (high digit): 8 + 4 = 12

(decimal 12 = hexidecimal C)

Decimal

Hexidecimal

Equivalent

0-9

0-9

10

A

11

B

12

C

13

D

14

E

15

F

1
2
4
8

DB5-8

DB1-4

1
2
4
8

1
2
4
8

DB5-8

DB1-4

1
2
4
8

Example:

= Unilluminated LED (0)

= Illuminated LED (1)

POST Code LEDs

Eight surface-mounted LEDs are located near one end of the 1UIPMI slot. These

LEDs are used to provide POST code information. See the diagrams below for

reading the LEDs and refer to Appendix B for a complete list of POST codes.

Toward edge of board

SCSI Activity LEDs

There are two SCSI activity LEDs on

the serverboard. When illuminated,

DA1 indicates activity on SCSI chan-

nel A and DA2 indicates activity on

SCSI channel B.

SCSI Channel Activity LEDs

(DA1/DA2)

State System Status

On

SCSI Channel Active

Off

SCSI Channel Inactive

Advertising