12 mode setting, Frame image output with a strobe light – Sony XC-EU50 User Manual

Page 12

Advertising
background image

12

Mode Setting

EXT HD

T

EXT VD

Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.

Sample input timing chart 2

Continuous signal: 15.734 kHz (XC-EU50) Allowable frequency value ±1%,

15.625 kHz (XC-EU50CE) Allowable frequency value ±1%

VD interval (T): 262.5 H or more (XC-EU50) and less than 1 second (Recommended),

312.5 H or more (XC-EU50CE) and less than 1 second (Recommended)

Four or more VD pulses are required.

Exposure time for the Odd field

Exposure time for the Even field

Frame Accumulation (Factory setting)

Video output

Invalid image

Odd
image

Even image

Valid frame image

1/60
second

1/60
second

Frame image output with a strobe light

The factory setting for this camera is Frame
Accumulation. The images obtained when the normal
continuous shutter or trigger shutter is used are field
images (vertical resolution: 243 lines).

Using a strobe light and Restart/Reset mode, you can
obtain bright frame images by synchronizing any
strobe light. (Vertical resolution: 485 lines).

EXT HD

EXT VD

Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.
Avoid lighting the scene during the light-emitting inhibit zone defined below. (The field is transfered to the
storage area of the CCD, so it can be read out.)

Note

For best performance, it is recommended that you not flash between VD and VD + 10 H (XC-EU50)/16 H
(XC-EU50CE).

Sample input timing chart

Continuous signal: 15.734 kHz (XC-EU50) Allowable frequency value ±1%,

15.625 kHz (XC-EU50CE) Allowable frequency value ±1%

VD: 1/60 sec (XC-EU50), 1/50 sec (XC-EU50CE)
Four or more VD pulses are required.

Strobe light

Exposure time for the Odd field

Exposure time for the Even field

Frame Accumulation (Factory setting)

Video output

Invalid image

Odd
image

Even
image

Valid frame image

Advertising