Mode Setting

For setting the shutter speed using the DIP switches

*1 This is a signal input from outside. The trigger

input frequency must be [Shutter speed (DIP
switches) + 1 field + 2 H frequency] or more. If
invalid data is input, normal operation is resumed
several Vs after entering the correct data.

*2 The exposure time (Te) is determined by the

setting of the DIP switches.

For details, see Page 10.

*3 The normal operation state is chosen when the

trigger pulse width is 1/3 s or more. The trigger
falling edge restores the external trigger shutter
operation. In this case, the area between the falling
edge of a trigger pulse and the subsequent 50 ms
period is an external trigger input inhibition area.
There is no guarantee of operation for any triggers
input in this period.

T*

4

External trigger shutter operation

Normal operation*

3

Mode transition state

External input

inhibition area

(50 ms)

External trigger

shutter operation

Exposure time (Te)*

2

Exposure time
(Te)*

2

Trigger pulse width*

3

Trigger*

1

Video out

WEN

T*

4

100

µ

s to 250 ms

*4 The image is output at the shortest timing from the

trigger rising edge according to the DIP switch
setting.

250 H (EIA)
293 H (CCIR)