15 mode setting, Sec (eia) te = trigger pulse width + 120 – Sony XC-EU50 User Manual

Page 15

Advertising
background image

15

Mode Setting

1

1

2

2

3

3

For setting the shutter speed using the trigger pulse width

No HD/VD input (Internal synchronization)

*1 This is a signal input from outside.

*2 Exposure time (Te)

Te = Trigger pulse width + 97

µ

sec (EIA)

Te = Trigger pulse width + 120

µ

sec (CCIR)

(The effective trigger pulse width for the external
trigger shutter operation is between 2

µ

s and 1/4 s.)

*3 The normal operation state is chosen when the

trigger pulse width is 1/3 s or more. The trigger
falling edge restores the external trigger shutter
operation. In this case, the area between the falling
edge of a trigger pulse and the subsequent 50 ms
period is an external trigger input inhibition area.
There is no guarantee of operation for any triggers
input in this period.

*4 The internal VD signals are output as long as there is

no external input and the HD/VD signal I/O switch
on the rear panel is set to INT.

*5 In the external trigger operation, the image is

output for the internal VD falling edge after the
trigger falling edge (1 and 2 in the figure). If the
period from the trigger falling edge to the internal
VD falling edge (T in the figure) is under 10

µ

s,

there may be a delay of 1 VD in the output. (3 in
the figure shows that the image is output for the
next internal VD). In this case, see WEN since the
image and WEN make up a pair. (The internal VD
falling edge and the beginning of the equivalent
pause in the V period of the SYNC have the same
phase.)

*6 When the external trigger shutter mode changes to

the normal operation mode, one WEN signal is
output.

Note

An image is not output correctly when the next trigger
is input before the image for the previous trigger is
output.

External trigger shutter operation

Normal operation*

3

Mode transition state

External input

inhibition area

(50 ms)

External trigger

shutter operation

Exposure
time (Te)*

2

Exposure time
(Te)*

2

Trigger pulse width

*

3

T: T=10

µ

s or more*

5

Trigger*

1

Internal HD*

4

Video out

WEN

Exposure
time (Te)*

2

T: T=under 10

µ

s*

5

250 H (EIA)
293 H (CCIR)

*