Control codes used for peripheral units, Other control codes – Star Micronics SP300 Series User Manual
Page 35

– 31 –
Control Codes Used for Peripheral Units
Control codes
Hexadecimal
Function
Page
codes
<ESC> <BEL> n1 n2
1B 07 n1 n2
Adjust drive pulse width for peripheral unit 1 49
<BEL>
07
Deferred drive command for peripheral unit 1
49
<FS>
1C
Immediate drive command for peripheral unit 1
49
<SUB>
1A
Immediate drive command for peripheral unit 2
50
<EM>
19
Immediate drive command for peripheral unit 1
50
Other Control Codes
Control codes
Hexadecimal
Function
Page
codes
<RS>
1E
Sound buzzer
50
<CAN>
18
Cancel print data in buffer & Initialize printer
50
<DC3>
13
Set deselect mode
51
<DC1>
11
Set select mode
51
<ESC> “U” “1”
1B 55 31
Select uni-directional print mode
52
<ESC> “U” <1>
1B 55 01
<ESC> “U” “0”
1B 55 30
Select bi-directional print mode
52
<ESC> “U” <0>
1B 55 00
<ESC> “@”
1B 40
Initialize printer
52
<ENQ>
05
Enquiry
53
<STX>
02
Enter STX-ETX mode
53
<ETX>
03
Terminate STX-ETX mode
53
<ESC> “d” “0”
1B 64 30
<ESC> “d” <0>
1B 64 00
Trigger auto-cutter drive
54
<ESC> “d” “1”
1B 64 31
(Auto-cutting models only)
<ESC> “d” <1>
1B 64 01
<GS>...<LF>
1D...0A
Selection of validation characters
54
(Models with validation function only)