7-6. Control Codes Used for Peripheral Units

FUNCTION

Adjust drive pulse width for peripheral unit 1

CODE

<ESC> <BEL> n1 n2
(1B)

H

(07)

H

n1 n2

DEFINITION RANGE

1

n1

127, 1

n2

127 (default setting n1 = n2 = 20)

OUTLINE

Adjusts drive pulse width for peripheral devices requiring
other than standard 200 ms pulse time and delay time
Energizing time = 10

×

n1 (ms)

Delay time = 10

×

n2 (ms)

Executed by <BEL>, <FS> codes.

NOTE

Adjustment is not necessary for standard cash drawers in the
U.S.A. market.

FUNCTION

Deferred drive command for peripheral unit 1

CODE

<BEL>
(07)

H

OUTLINE

Executes drive pulse for peripheral unit 1 (deferred).

FUNCTION

Immediate drive command for peripheral unit 1

CODE

<FS>
(1C)

H

OUTLINE

Executes drive pulse for peripheral unit 1 (immediate).
This code differs from the <BEL> code as follows:
When the printer receives an <FS> code, the command is
executed immediately. The <BEL> code is stored in the data
buffer in the same manner as other codes, and executed in the
order in which they are received.