STORAGE TIPS

If you do not plan to use your humidifier for an extended period of time, such
as during the summer months, it is important that you follow these instructions
to help prevent problems from developing in the unit.

1. Clean your humidifier as instructed in the section titled, “Cleaning and

Maintenance”.

2. Make sure all water is emptied from the tank and the hot and cold water

reservoirs.

3. Dry your unit thoroughly.
4. Leave the tank cap off to expose the tank to air.
5. Pack your humidifier in its original carton and store it in a cool, dry place.

SERVICE

DO NOT attempt to repair this humidifier yourself. For repairs covered under
the warranty, contact Slant/Fin by telephone or mail for a Return Authorization
Number.

TROUBLESHOOTING

TROUBLE POSSIBLE

CAUSES

SOLUTION

Unit does not mist

Unit is not plugged in

Plug in unit

Power failure

Check circuit breaker

Water tank empty

Remove and refill

Power switch not turned on

Turn on switch

Unit still on “REFILL” after

Check that there is

refilling tank

water in the hot water
reservoir.

Float on bottom of tank

Carefully clean any

“hangs up”

residue or obstruction

Water tank not properly

Reposition water tank

located on base unit
Humidity level set is achieved

Turn Relative
Humidity Control to
higher setting

Water leaks from unit

Drain cap, drain cap gasket,

Tighten cap. Replace

tank cap or tank cap gasket

or reposition cap

is missing or improperly

gasket.

positioned.

Moist air output low

Mineral buildup in hot water

Clean unit as per

reservoir.

instructions.

No mineral buildup.

Check ambient
humidity. If humidity
is high, output will
be low.

9