A.3 environmental requirements, Table a-9, Table a-10 – Sun Microsystems 6.0005E+11 User Manual
Page 224

A-4
Ultra Enterprise 6000/5000/4000 Systems Manual—November 1996
A
A.3 Environmental Requirements
BTU rating
4680 BTU
Power factor
0.92 - 0.96
Plug type
U.S.
NEMA 5-15P
International
10A, single phase IEC 320,
connected for 220-240 Vac
Table A-9 Cabinet Server Temperature, Humidity,
and Altitude Limits
Operating
Nonoperating
Temperature
41
°
F to 95
°
F (5
°
C to 35
°
C)*
-4
°
F to 140
°
F (-20
°
C to 60
°
C)
Humidity
20% to 80% RH noncondensing,
27C max wb
93% RH
Altitude
9,843 ft (3 km)
39,370 ft (12 km)
*Maximum operating temperature is 95
°
F (35
°
C) when using tape media.
Table A-10 Standalone Server Temperature, Humidity,
and Altitude Limits
Operating
Nonoperating
Temperature
41
°
F to 104
°
F (5
°
C to 40
°
C)*
-4
°
F to 140
°
F (-20
°
C to 60
°
C)
Humidity
20% to 80% RH noncondensing,
27C max wb
93% RH
Altitude
9,843 ft (3 km)
39,370 ft (12 km)
*Maximum operating temperature is 95
°
F (35
°
C) when using tape media.
Table A-8 Standalone Server Electrical Specifications (Continued)
Parameter
Value