0 circuit board pin assignments, Danger – Sundance Spas ALTAMAR 880 User Manual

Page 74

Advertising
background image

Page 68

880 SERIES

20.0 Circuit Board Pin Assignments

850 LCD

REVX.XX

JP20
JP19

JP9

1
1

3

5

7

9

1

3

5

7

9

11

13

JP20
JP19

JP9

1
1

3

5

7

9

1

3

5

7

9

11

13

DANGER

Turn power off
before servicing. This
task should only be
performed by a quali-
fied technician.

!

RISK OF SHOCK OR
ELECTROCUTION!

Refer to pages 15-16 for additional jumper configuration details.

JP20-1

Not Used

JP19-1

On =°C Off =°F

JP19-3

Not Used

JP19-5

Enables the logic for the Multi Color LED Light

JP19-7

Not used

JP19-9

Not Used

JP9-1

On

JP9-3

Not Used

JP9-5

Not used

JP9-7

On = 60A Logic Off = 40/50A Logic (See Section 7.0

pages 15-16 for logic details)

JP9-9

On = 2 or 3 Pump Logic Off = 1 Pump Logic

JP9-11

On = 40A Logic (See pages 15-16 for logic details)

JP9-13

Not used