Sub-Zero 315W User Manual

Page 17

Advertising
background image

17

S U B - Z E R O

T R O U B L E S H O OT I N G

G U I D E

T R O U B L E S H O OT I N G

G U I D E

P R O B L E M

P O S S I B L E C A U S E

P O S S I B L E S O L U T I O N

Cabinet too warm

Unit switched off

Check temperature control

Cabinet temperature

Temperature control setting

Check temperature setting

changed

changed

Excessive operating time

Dirty condenser

Clean condenser

Cabinet full of warm wine

Unit must operate for up to 24
hours to cool warm wine

Door gasket not sealing tightly

Check gasket fit

Thick frost on evaporator

Shut unit off until frost melts,

(see below)

(see below)

Unit in warm room conditions

Sunlight or high room tempera-
tures will increase operating time

Excessive noise

Fan will make some noise

May be normal

Unit will not cool

Fan blade contacting fan shroud

Check for free fan blade rotation

Dirty condenser

Clean condenser

Fan motor not turning blade

Contact authorized service center

Low on refrigerant

Contact authorized service center

Compressor not operating

Contact authorized service center

Thick frost on evaporator

Door gasket not sealing tightly

Check gasket fit

Door not closing

Check door for obstructions

Thermostat not keeping unit off

Contact authorized service center

long enough

Excessive operating time

Check for cause (see above)

Cabinet light does not

Light bulb burned out

Replace light bulb (see page 15)

work properly

Door switch does not close

Check door switch

Cannot switch light on with

Check rocker switch

door closed

Water running inside unit

Drain trough hose plugged

Contact authorized service center

Water leaking under unit

Drain hose out of position

Contact authorized service center

Drain pan over filling

Check door or door gasket

S E R V I C E
C E N T E R

Contact your
Sub-Zero dealer or
check the Locator
section of our
website,
subzero.com, for
the authorized
service center
nearest you.

Advertising