Symptom

Cause/Remedy

The output from S VIDEO OUT jack and
VIDEO OUT jack is different from [DOWN
CONVERT] setting of [VIDEO OUT] in [IN/
OUT REC].

The output from S VIDEO jack and VIDEO jack is set as follows.
• When the playback format is set shown below, the output from S VIDEO jack or

VIDEO jack is fixed in EDGE CROP.

• When the playback format is set shown below, the output from S VIDEO jack or

VIDEO jack is fixed in LETTER BOX.

Menu item

Setting

Playback format

HDV (HDV1080i)

[VIDEO OUT] in

[DOWN CONVERT]

SQUEEZE or
LETTER BOX

[IN/OUT REC]

[HDMI/CMPNT]

480p/480i, 576p/576i

[i.LINK SET] in

[HDV

t DV CONV]

DVCAM or DV SP

[IN/OUT REC]

[DOWN CONVERT]

Set to EDGE CROP

Menu item

Setting

Playback format

HDV (HDV1080i or
HDV720p)

[VIDEO OUT] in

[HDMI/CMPNT]

480i, 576i, 480p/480i,

[IN/OUT REC]

576p/576i

[ALLSCAN MODE] in [DISPLAY SET]

ON

Recording/Dubbing

Symptom

Cause/Remedy

Whenever you connect the unit to an AC
outlet, the unit automatically starts
recording.

Even though KEY INH switch is set to ON,
the unit starts recording/playback by itself.

No picture is output via HDV/DV jack.

• TIMER switch is set to REC.

t When TIMER switch is set to REC, the unit starts recording whenever the

power is connected. Set TIMER switch to OFF.

• TIMER switch is set to REPEAT or REC.

t TIMER switch setting has a higher priority than KEY INH switch setting. Set

TIMER switch to OFF.

• When [COMMANDER] in [OTHERS] menu is set to [WIRELESS], the unit

responds to signals from Remote Commander even though KEY INH switch is set
to ON.
t Set [COMMANDER] to [CONTROL S].

t Reconnect the i.LINK cable (not supplied).
• INPUT SELECT switch is set to a position other than HDV/DV.

t Set the switch to HDV/DV.
t Set [HDV/DV SEL] in [IN/OUT REC] menu correctly.

(Continued)