Appendix

Note:

• The overlapping area might become uneven depending on the images. In such a case, it is recommended to

decrease the contrast of the images in the Image Adjust Menu or set the BrilliantColor function to ‘Off’.

If the colors of the left and right images do not match, then follow the next step.

Select ‘Color matching’ in the setting menu and display the Color matching dialog box.

Then, set ‘Color matching’ to ‘On’ and adjust the color settings (Red/Green/Blue/White).

(Refer to page 53 for operation procedure.)

6

Color matching

Note:

• When you change the values of Target, make sure that each

Target value should be within the range of Measured value.

(e.g., In the case of the Fig.1, the X value of Target-Red

should be within 0.623 which is the X value of Measured-

Red.)

Set to ‘On’.

5

Set ‘Test pattern’ to ‘On’ to display a 50 % white image. The overlap area will be brighter than the non-overlapping

area. Adjust the Black level in the Edge blending dialog box to increase the brightness of the non-overlapping area so

that the unevenness is reduced.

Select ‘Advanced color matching’ if you need further adjustment.

In the Advanced color matching dialog box, set ‘Advanced color matching’ to ‘On’ and adjust the values of Target (Red/

Green/ Blue/ Cyan/ Magenta/ Yellow/ White).

7

Fig .1 For rich color reproduction color wheel

If the colors of the left and right images do not match, even

if the Target values are adjusted, use a colorimeter which

is capable of measuring the chromaticity coordinates and

luminance. Follow the steps below.

1. Set ‘Auto test pattern’ to ‘On’ in the Advanced color

matching dialog box.

2. Put the cursor in the Mesured-White and press the

SELECT button to display a white pattern.

3. Measure the chromaticity coordinates (x,y) and

luminance (lx) by using the colorimeter.

4. Enter the obtained (x,y) values in the Mesured-White.

(The (L) value of Mesured-White should be left at 1.000.)

5. Put the cursor in the Mesured-Red and press the SELECT

button to display a red pattern.

6. Measure the chromaticity coordinates (x,y) and

luminance (Lx) by using the colorimeter.

7. Enter the obtained (x,y) values in the Mesured-Red. Then,

calculate the (L) value of Mesured-Red by applying the

following formula and enter the value.

(L) value of Mesured-Red = [Lx of Red] ÷ [Lx of White]

8. Enter the values of Mesured-Green, Mesured-Blue, and

Mesured-Half white in the same way as Mesured-Red.

9. Adjust the values of Target again.
10. Select ‘Store’ to complete. (Apply the same adjustment

to the other projector if necessary.)