4. control codes used for peripheral units, 5. auto cutter control (sp240 type only), 6. other control codes – Star Micronics SP200F SERIES User Manual
Page 23

– 20 –
ENGLISH
6-4. Control Codes Used for Peripheral Units
Control codes
Hexadecimal codes
Function
<ESC> <BEL> n1 n2
1B 07 n1 n2
Adjust drive pulse width for peripheral unit (Default
setting)
<BEL>
07
Deferred drive command “A” for peripheral unit 1
<FS>
1C
Immediate drive command “B” for peripheral unit 1
6-5. Auto Cutter Control (SP240 type only)
Control codes
Hexadecimal codes
Function
<ESC> “d” “0”
1B 64 30
Full-cut command to the auto cutter
<ESC> “d” <0>
1B 64 00
<ESC> “d” “1”
1B 64 31
Partial-cut command to the auto cutter
<ESC> “d” <1>
1B 64 01
<ESC> “d” “2”
1B 64 32
Full-cut command to the auto cutter
<ESC> “d” <2>
1B 64 02
after paper feed
<ESC> “d” “3”
1B 64 33
Partial-cut command to the auto cutter after paper
<ESC> “d” <3>
1B 64 03
feed
6-6. Other Control Codes
Control codes
Hexadecimal codes
Function
<CAN>
18
Cancel print data in buffer
<ENQ>
*
1
05
Enquiry
<DC1>
*
1
11
Set select mode
<DC3>
*
1
13
Deselect printer
<ESC> “@”
1B 40
Initialize printer
<ESC> “e” “0”
1B 65 30
ON LINE/FEED switch valid
<ESC> “e” <0>
1B 65 00
(Default setting)
<ESC> “e” “1”
1B 65 31
ON LINE/FEED switch invalid
<ESC> “e” <1>
1B 65 01
<ESC> “f” “0”
1B 66 30
ON LINE switch valid
<ESC> “f” <0>
1B 66 00
(Default setting)
<ESC> “f” “1”
1B 66 31
ON LINE switch invalid
<ESC> “f” <1>
1B 66 01
*
1
: Valid for the RS-422A only.