Data transmission rate (baud rate), Appendix – Star Micronics SP200F SERIES User Manual
Page 93
Advertising

– 90 –
APPENDIX
Data transmission rate (baud rate)
Baud rate
Switch 6
Switch 7
1200
OFF
OFF
2400
OFF
ON
4800
ON
OFF
9600
ON
ON
DIP SW 2 (RS-422A interface only)
All switch settings are ON when the
printer is shipped from the factory.
SW
Function
ON
OFF
2-1
2-2
Device address
See table below
2-3
2-4
2-5
When turning
DC1, DC3 valid mode
Select
Deselect
the power on.
DC1, DC3 invalid mode
(Not used)
Addressable mode
Deselect
Select
2-6
Data composition
XON/XOFF
DTR
Mode DC1
Addressable mode
DC1
DC3
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
#12
#13
#14
DC3
invalid
valid
mode
mode
1
ON
OFF ON OFF ON
OFF ON
OFF ON OFF
ON OFF ON OFF ON
OFF
2
ON
ON OFF OFF ON
ON OFF OFF ON
ON
OFF OFF ON
ON OFF OFF
3
ON
ON
ON
ON OFF OFF OFF OFF ON
ON
ON
ON OFF OFF OFF OFF
4
ON
ON
ON
ON
ON
ON ON
ON OFF OFF OFF OFF OFF OFF OFF OFF
Advertising