Rewiring W1773 to 440V

Rewiring your Model W1773 to 440V requires you to

replace the existing control box 220V main panel with a

440V main panel and rewire the sanding motor and feed

motor.

The 440V conversion kit can be purchased as #X1773553 by

calling (360) 734-3482.

The rewiring job must be inspected by a qualified electri-

cian before connecting to power.

To rewire the Model W1773 for 440V operation, do these

steps:

1. DISCONNECT THE SANDER FROM THE POWER SOURCE!

2. Rewire both the sanding drum and feed motors accord-

ing to the diagrams on the inside of the junction box

cover.

Note: These drawings are also shown on Page 54 & 55

for your reference, but always use the drawings in the

junction box cover, as they will reflect any changes to

the machine since the time of writing.

3. Open the control panel and familiarize yourself with

Figure 75 on Page 50 for component locations.

4. Keeping track of the wire locations, disconnect all

power and motor wires, so the main panel can be com-

pletely removed.

5. Remove and replace the existing control box 220V

main panel with the 440V main panel from the 440V

conversion kit (

Figure 4).

6. Connect the power and motor wires to the new main

panel in the same manner that they were removed

from the old panel.

7. Make sure the thermal relays are set to the following

values for 440V:

Feed Motor Relay = 0.65A

Sanding Motor Relay = 21.5A

8. Have the wiring job inspected by a qualified electri-

cian.

Figure 5. W1773 3-phase 440V thermal

overload relay values.

Feed Drum

Relay

Sanding Drum

Relay

Figure 4. W1773 control box main panel,

3-phase 440V.