-25-

W1772/W1773 37" Drum Sander

O

PE

R

AT

IO

N

S

Sanding

To sand a workpiece, do these steps:

1. Adjust the table height according to the instructions

in

Depth of Cut on Page 24.

2. Start the dust collector, the drum motor, and the

feed motor.

3. Feed the workpiece through the sander while stand-

ing to the side and monitor the amp meter; if it

approaches the maximum amp load, lower the con-

veyor table.

4. Run wide stock through two or three times with-

out adjusting the table height. Turn the stock 180°

between passes to ensure an even cut. Do not sand

more than one workpiece at a time side-by-side.

DO NOT sand more than one board at

a time side-by-side. Minor variations

in thickness can cause one board to

be propelled by the rapidly spinning

sanding drum and ejected from the

machine. NEVER stand directly in front

of the machine. Failure to do so could

result in severe personal injury.

Close all covers and panels before

starting the drum sander. Failure to

do so could result in severe personal

injury.

Using the Amp Draw

Meter

The amp draw meter (

Figu

re 26

) is used to keep

the

machine from being overloaded during sanding

operati

ons.

As a general rule, always start with a shallow sand-

ing depth and carefully increase the sanding depth.

Keep the amp load in the green range during operation.

Generally, the normal depth of cut is no more than

1

64

"

or 0.016" for a 36

1

/

2

" wide board using coarse sandpaper.

DO NOT work your machine in the red zone as shown on

the Amperage Load Chart. If operated in the red zone,

the motor will lose RPM, the start capacitor will ener-

gize, and capacitor or motor damage will occur.

Amp load is directly affected by many factors such as

feed rate, depth of cut, wood type, sandpaper grit, and

workpiece width.

W1772 Maximum Amp Load ............................. 44A

W1773 Maximum Amp Load at 220V .................. 40A

W1773 Maximum Amp Load at 440V .................. 20A

������������������������

�������������������

������������������������

�������������������

�����

�����

�����

������

������

���

�����

������

���

����

����

������

������

�������

�������

�����

�����

��

����

������

�������

Figure 28. W1773 amp load chart.

������������������������

�������������������

������������������������

�������������������

�����

�����

�����

������

������

���

�����

������

���

����

����

������

������

�������

�������

�����

�����

��

����

������

�������

Figure 27.W1772 amp load chart.

Figure 26. Amp draw meter.

Advertising