12. SERVICE PROCEDURES

3)

Outdoor Unit does not Run.

A. Check COOL / FAN selector switch in the remote control unit.

B. Check set temperature.

0624_X_S

Try to lower set
temperature by Temperature
setting button “COOLER”.

• Set “Operation selector”
switch to TEST in the
indoor unit.

YES

Outdoor unit runs.

Is room temperature too
low ?

NO

• Try to run both indoor and
outdoor units with another
remote control unit.

OK

The other remote control
unit is defective.
(Room sensor in the remote
control unit is defective.)

0623_X_S

• Is COOL/FAN selector switch
set to COOL ?

NO

Set to COOL.

Advertising
This manual is related to the following products: