Sanyo CL2472 User Manual

Page 95

Advertising
background image

6

2-3. Baffle Plate for the Outdoor Unit

(CLxx models only)

It is recommended to use baffle plates for models

CL1872 and CL2472. The baffle plates are not normally

required for the other models.

When the outdoor unit is installed in a position exposed

to strong wind (such as seasonal winds with low air tem-

perature in winter), baffle plates must be installed on the

outdoor unit. (Fig. 5f)

This unit is designed so that the fan of the outdoor unit

runs at low speed when the air conditioner is operated at

low outdoor air temperatures. When the outdoor unit is

exposed to strong wind, the system pressure drops

because of the freeze protector.

Install a pair of windbaffle plates at the front and back of

the outdoor unit if it will be subject to strong wind during

the winter. (Figs. 5f, 5g, 5h, 5i, and 5j)

NOTE

Fig. 5f

Air discharge baffle

Wind

Front

Air intake baffle

No air intake baffle
required on
this side.

Wind

Back