4] error code table, Communication error code table g3 transmission, G3 reception – Sharp FO-475TH User Manual

Page 27

Advertising
background image

UX-258TH
FO-475TH

[4] Error code table

1. Communication error code table

G3 Transmission

Code

Final received signal

Error Condition (Receiver side)

0

Incomplete signal frame

Cannot recognize bit stream after flag

1

NSF, DIS

Cannot recognize DCS signal by echo etc.

Cannot recognize NSS signal (FIF code etc)

2

CFR

Disconnects line during reception (carrier missing etc)

3

FTT

Disconnects line by fall back

4

MCF

Disconnects line during reception of multi page

Cannot recognize NSS, DCS signal in the case of mode change

5

PIP or PIN

The line is hung up without replying to telephone request from the receiving party.

6

RTN or RTP

Cannot recognize NSS, DCS signal after transmit RTN or RTP signal.

7

No signal or DCN

No response in receiver side or DCN signal received* (transmitter side)

8

−

Owing to error in some page the error could not be corrected although the specified number of

error retransmission was at tempted.

11

−

Error occurred after or while reception by the remote (receiving) machine was revealed to be

impossible.

12

−

Error occurred just after fallback.

13

−

Error occurred after a response to retransmission end command was received.

G3 Reception

Code

Final received signal

Error Condition (Receiver side)

0

Incomplete signal frame

Cannot recognize bit stream after flag

1

NSS, DCS

Cannot recognize CFR or FTT signal

Disconnects line during transmission (line error)

2

NSC, DTC

Cannot recognize NSS signal (FIF code etc)

3

EOP

Cannot recognize MCF, PIP, PIN, RTN, RTP signal

4

EOM

Cannot recognize MCF, PIP, PIN, RTN, RTP signal in the case of mode change

5

MPS

The line is hung up without replying to communication request.

6

PR1-Q

Cannot recognize PIP, PIN signal in the case of TALK request

7

No signal or DCN

No response in transmitter (cannot recognize DIS signal) or DCN signal received* (receiver side)

8

−

Error occurred upon completion of reception of all pages.

9

−

Error occurred when mode was changed or Transmission/Reception switching was performed.

10

−

Error occurred during partial page or physical page reception.

11

−

Error occurred after or during inquiry from the remote (transmitting) machine as to whether

reception is possible or not.

12

−

Error occurred during or just after fallback.

13

−

Error occurred after the retransmission end command was received.

2 – 18

Advertising
This manual is related to the following products: