– 13 –
(2) Ribbon Shift Operation (Only with 2 color printing on the MP115)
Fig. 3-8 Release action
Release Action
MOTOR
TIMING SIG-1
RIBBON SHIFT
RIBBON SHIFT GEAR
ON
OFF
ON
OFF
ROTATE
STOP
HIGH
LOW
18 Pulses
T30
T1 T2T3
T336
288 Pulses
Ribbon shift gear rotation: 
18 x 6 x 32/12 = 288 pulses