3.12 Home Position Detector (HP-sig) Specifications

The home position detector is composed of the mechanical switch. While the carriage is located at the left

end, the switch remains ON.

R1

10 k

R2

15 k

C1

0.022

µ

F

Fig. 3-21 Home position detector circuit (example)

In order to improve reliability, we recommend that the HP-sig is detected as described below.

(1) When the T1-sig is unstable when turning on the power, etc.

Detect the L level after having detected the H level of the HP-sig, and then, after having carried out 81

pulse counts for the T1-sig, detect the H level.

(2) When the T1-sig is decided during continuous operation of the motor

Detect the L level of the HP-sig, and then, after having counted 847 pulses of the T1-sig, detect the H

level.

3.13 Paper-out Detector (PE-sig) Specifications

The Paper-out Detector is composed of a mechanical switch. While the paper is set in the paper tray, the

switch remains ON.

R1

10 k

R2

15 k

C1

0.022

µ

F

Fig. 3-22 Paper-out detector circuit (example)