– 16 –

(2)

Pre-fire

This operation applies minute vibrations to the needle wire to allow for its smooth movement as printer warmup.

Pre-fire is performed under the following conditions. The energizing time is too short to allow for the printing

action to occur.

Operating time

When power is turned ON.

Number of times

32 Times

Frequency

900 Hz

Power supply voltage

DC24V

±

2.4 V

Energizing time

175

±

5

µ

s

(3)

Print Duty

This print head is not equipped with a head temperature detector. Therefore, use the printer within the maxi-

mum printing ratio shown below. If you print exceeding this printing ratio, you can damage the printer.

Fig. 3-12 Print duty

The figure above shows the print duty that is possible with continuous printing when each wire is used an

equivalent number of times. In this case, you can calculate the possible dot count for D per character using the

following numerical formula.

N (Print Ratio) x T (Print time per line includes the time of the paper feed [sec])

L (number of character per line)

[dot/chara]

1140

830

21.6 V

24.0 V

26.4 V

Ambient Temperature 25

°

C

Ambient Temperature 50

°

C

Print Ratio N
(dot /sec)

Advertising