31 enforcer mini ptz camera seco-larm, u.s.a., inc, System initialize menu – SECO-LARM USA Mini PTZ Camera EV-7105-PPEQ User Manual

Page 30

Advertising
background image


31

ENFORCER Mini PTZ Camera

SECO-LARM, U.S.A., INC.







































NO ACTION ### DWELL OPT

1

PRESET 1 00 : 03 : 360

2

NONE

3

NONE

4

NONE

5

NONE

EDIT GROUP 1

CANCEL

[FAR : EDIT :END]

SAVE

[NEAR:EDIT ACT]

4. Configure each ACTION, ###, DWELL, and OPT.

In the sample screen on the left, ACTION #1 is the

command for the PTZ camera to go to PRESET #1 using

the PRESET speed of 360 as programmed in the PRESET

SETUP menu (see page 26), and stay at that position for 3

seconds before moving to the next action.

5. After setting up an ACTION, use the NEAR key to move the

cursor to the NO column, and then move the cursor up and

down to select another ACTION to configure or modify.

6. After setting up all the ACTIONs for this GROUP, press the

FAR key to exit. At this point, the cursor will move to SAVE.

Press the NEAR key to save the data.

NO ACTION ### DWELL OPT

1

PRESET 1 00 : 03 : 360

2

NONE

3

NONE

4

NONE

5

NONE

EDIT GROUP 1

CANCEL

[

▲▼:CHANGE VAL.]

SAVE

[

◄►:MOVE CURSOR]

NO ACTION ### DWELL OPT

1

PRESET 1 00 : 03 : 360

2

NONE

3

NONE

4

NONE

5

NONE

EDIT GROUP 1

CANCEL

SAVE

SYSTEM INITIALIZE Menu

From SPEED DOME CAMERA

CLEAR ALL DATA

NO

•CLR DISPLAY SET

NO

•CLR CAMERA SET

NO

•CLR MOTION SET

NO

•CLR EDIT DATA

NO

REBOOT CAMERA

NO

REBOOT SYSTEM

NO

SYSTEM INITIALIZE

EXIT

SAVE

This menu lets the user clear selected programmed data, clear all

programmed data, or reboot the entire camera or system.

CLEAR ALL DATA

Deletes all user-programmed data including

DISPLAY SETUP, CAMERA SETUP, and

MOTION SETUP.

CLR DISPLAY SET

Clears the DISPLAY SETUP data and initializes

the configuration of that data.

CLR CAMERA SET

Clears the CAMERA SETUP data and initializes

the configuration of that data.

CLR MOTION SET

Clears the MOTION SETUP data and initializes

the configuration of that data.

CLR EDIT DATA

Deletes all PRESET SETUP data, SWING SETUP

data, PATTERN SETUP data, and GROUP

SETUP data.

REBOOT CAMERA

Reboots the zoom camera module.

REBOOT SYSTEM

Reboots the entire PTZ camera.

Advertising