NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

16

If the vent system extends more than 5 feet

(1.5 meters) above the roof flashing, stabilizers

may be necessary. Additional screws may be

used at section joints for added stability. Guide

wires may be attached to the joint for additional

support on multiple joint configurations.

Align the termination over the end of the pre-

viously installed section, adjusting the radial

alignment until the four locking dimples of

the termination are aligned with the inlets of

the four incline channels of the last vent sec-

tion. Push the termination down until it fully

engages, then twist the termination clockwise

running the dimples down and along the incline

channels until they are seated at the end of the

channels.

I. Install the roof flashing - Extend the vent

sections through the roof structure. Install the

roof flashing over the vent section and posi-

tion such that the vent column rises vertically

(use carpenters level) (Figure 27). Nail along

perimeter to secure flashing or adjust roofing

to overlap the flashing edges at top and sides

only and trim where necessary. Seal the top

and both sides of the flashing with waterproof

caulking.

Figure 27

Storm

Collar

Figure 28

Framing Dimensions for Roof

Inches (millimeters)

Pitch

C

D

0/12

10-1/2 in.

(267 mm)

10-1/2 in.

(267 mm)

6/12

10-1/2 in.

(267 mm)

12 in.

(305 mm)

12/12

10-1/2 in.

(267 mm)

17 3/4 in.

(451 mm)

C

D

Figure 26

- Roof Framing

J. Install the storm collar - Install the storm

collar, supplied with the flashing, over the

vent/flashing joint. See Figure 27. Loosen the

storm collar screw. Slide collar down until it

meets the top of the flashing. Tighten the ad-

justing screw. Apply non-combustible caulking

or mastic around the circumference of the joint

to provide a water tight seal.

K. Install the vertical termination - The final

step involves installation of the SV4.5CGV-1

Vertical Termination. Extend the vent sections

to the height as shown in the "Vertical vent ter-

mination section" on Page 6. The SV4.5CGV-1

Vertical Termination (Figure 28) can be installed

in the exact same fashion as any other Secure

Vent section.