Figure 3, Typical locations, Manufactured home requirements – Superior SDV35 User Manual

Page 5

Advertising
background image

5

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

CAUTION: This appliance must be
grounded to the chassis of the manu-
factured home in accordance with local
codes or in the absence of local codes,
with the National Electrical Code ANSI
/ NFPA 70 - latest edition or the Cana-
dian Electrical Code CSA C22.1 - latest
edition.

LOCATION

In selecting the location, the aesthetic and

functional use of the appliance are primary

concerns. However, vent system routing to

the exterior and access to the fuel supply are

also important.

Due to high temperatures, the appliance

should be located out of traffic and away from

furniture and draperies (Figure 3).

En raison des températures élevées,

l’appareil devrait être installé dans un endroit

où il y a peu de circulation et loin du mobilier

et des tentures (Figure 3).

The location should also be free of electrical,

plumbing or other heating/air conditioning

ducting.

These direct-vent appliances are uniquely suited

for installations requiring a utility shelf positioned

directly above the fireplace. Utility shelves like

these are commonly used for locating television

sets and decorative plants.

Be aware that this is a heat producing ap-

pliance. Objects placed above the unit are

exposed to elevated temperatures.

Do not insulate the space between the ap-

pliance and the area above it (see Figure 8

on Page 8).

The minimum height from the base of the appli-

ance to the underside of combustible materials

used to construct a utility shelf in this fashion

is shown in Figure 8 on Page 8.

The appliance should be mounted on a fully

supported base extending the full width and

depth of the unit. The appliance may be located

on or near conventional construction materials.

However, if installed on combustible materials,

such as carpeting, vinyl tile, etc., a metal or

wood barrier covering the entire bottom surface

must be used.

N

O

IT

A

CI

L

P

P

A

T

N

E

V

R

A

E

R

N

O

IT

A

CI

L

P

P

A

T

N

E

V

P

O

T

APPLICATION

TOP VENT

TN

EV

RA

ER

NOI

TA

CI

LP

PA
TN

EV

PO

T

NOI

TA

CI

LP

PA

RECESSED

INSTALLATION

TOP VENT

APPLICATION

NOI

TA

CI

LP

PA

TN

EV

PO

T

NOI

TA

CI

LP

PA

TN

EV

PO

T

(Rear Vent

VERTICAL VENT

Application)

(Rear Vent Application

HORIZONTAL VENT

without a chase)

HORIZONTAL VENT

(Rear Vent Application

With a chase)

HORIZONTAL VENT

(Top Vent

Application)

VERTICAL VENT

(Top Vent

Application)

Figure 3

-

Typical Locations

COLD CLIMATE INSULATION

For cold climate installations, seal all cracks

around the appliance with noncombustible

material and wherever cold air could enter

the room. It is especially important to insulate

outside chase cavity between studs and under

floor on which the appliance rests, if floor is

above ground level. Gas line holes and other

openings should be caulked or stuffed with

unfaced fiberglass insulation. If the fireplace

is being installed on a cement slab, in cold

climates, a sheet of plywood or other raised

platform can be placed underneath to prevent

conducting cold up into the room. It also helps to

sheetrock inside surfaces and tape for maximum

air tightness and caulk firestops.

MANUFACTURED HOME

REQUIREMENTS

This appliance may be installed in an aftermar-

ket permanently located, manufactured home

(USA only) or Manufactured Home, where not

prohibited by local codes.

This appliance may be installed as an OEM

installation in a manufactured home (USA

only) or Manufactured Home and must be

installed in accordance with the manufacturer's

instructions and the Manufactured Home

Construction and Safety Standard, Title 24

CPF, Part 3280 or Standard for Installation

in Manufactured Homes, CAN/CSA Z240 MH.

Cet appareil peut être installé comme du

matériel d'origine dans une maison préfabri-

quée (É.-U. seulement) ou mobile et doit être

installé selon les instructions du fabricant et

conformément à la norme Manufactured Home

Construction and Safety Standard, Title 24 CPF,

Part 3280 ou à la norme CAN/CSA Z240 Série

MM, Maisons Mobiles.

Cet appareil peut être installé dans un maison

préfabriquée (É.-U. seulement) ou mobile déjà

installée à demeure si les réglements locaux

le permettent.

This appliance is only for use with the type of gas

indicated on the rating plate. This appliance is

not convertible for use with other gases, unless

a certified kit is used.

Cet appareil doit être utilisé uniquement avec le

type de gaz indiqué sur la plaque signalétique.

Cet appareil ne peut être converti à d'autres gaz,

sauf si une trousse de conversion est utilisée.

CAUTION: Ensure that the cross mem-
bers are not cut or weakened during
installation. The structural integrity of
the manufactured home floor, wall, and
ceiling / roof must be maintained.