NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SIT Millivolt Gas Valve

Pressure

Regulator

Remove

These

Components

Figure 59

INSTALLATION INSTRUCTIONS

Step 1. TURN OFF THE GAS SUPPLY TO THE

APPLIANCE and disconnect power supply at the

circuit breaker. Ensure appliance is cold.

CAUTION: THE GAS SUPPLY SHALL BE

SHUT OFF PRIOR TO DISCONNECTING THE

ELECTRICAL POWER, BEFORE PROCEED-

ING WITH THE CONVERSION.

ATTENTION : AVANT D’EFFECTUER

LA CONVERSION, COUPEZ D’ABORD

L’ALIMENTATION EN GAZ, ENSUITE,

COUPEZ L’ALIMENTATION éLECTRIQUE.

Step 2. Remove the front glass door assembly

from the appliance (see Removing Glass Enclo-

sure Panels on Page 30). Remove the control

compartment door (see Control Compartment

Door Removal on Page 26).

Step 3. Carefully remove the logs. Exercise care

so as not to break the logs.

Step 4. Locate the screws securing the burner

assembly to the appliance. Remove the burner

assembly and retain the securing screws.

Step 5. - SIT Systems - Refer to Figure 59 and

the instructions provided with the kit. Using a

Torx T20 (with 1/4" shank and center hole), tool

or standard flat screwdriver remove and discard

the three pressure regulator mounting screws.

Remove the pressure regulator, spring, poppet,

diaphragm and bushing. Discard all removed

components.

Ensure the rubber gasket installed on the back of

the replacement pressure regulator is properly

positioned and install the new pressure regula-

tor using the new screws supplied with the kit.

Tighten screws to 25 In. lb. torque.

36

Millivolt SIT Systems

Propane to Natural Gas

Conversion Kits

Model

Cat. No.

SDV35

85L66

Millivolt HONEYWELL Systems

Natural Gas To Propane Gas

Conversion Kits

Model

Cat. No.

SDV35

11M37

Millivolt SIT Systems

Natural Gas To Propane Gas

Conversion Kits

Model

Cat. No.

SDV35

85L59

Millivolt HONEYWELL Systems

Propane Gas To Natural Gas

Conversion Kits

Model

Cat. No.

SDV35

11M34

In Canada:

THE CONVERSION SHALL BE CAR-

RIED OUT IN ACCORDANCE WITH THE

REQUIREMENTS OF THE PROVINCIAL

AUTHORITIES HAVING JURISDICTION

AND IN ACCORDANCE WITH THE RE-

QUIREMENTS OF THE CAN/CSA-B149.1

INSTALLATION CODE.

LA CONVERSION DEVRA êTRE EFFECTUéE

CONFORMéMENT AUX RECOMMANDA-

TIONS DES AUTORITéS PROVINCIALES

AYANT JURIDICTION ET CONFORMé-

MENT AUX EXIGENCES DU CODE

D'INSTALLATION CAN/CSA-B149.1.

Gas conversion kits are available to adapt your

appliance from the use of one type of gas to

the use of another. These kits contain all the

necessary components needed to complete

the task including labeling that must be af-

fixed to ensure safe operation.

Kit part numbers are listed here and the

following steps detail the conversion pro-

cedure. Refer to the instructions provided

with the conversion kit when performing any

gas conversion.

GAS CONVERSION KITS

WARNING

This conversion kit shall be installed by a qualified service agency in accor-

dance with the manufacturer’s instructions and all applicable codes and

requirements of the authority having jurisdiction. If the information in these

instruction is not followed exactly, a fire, explosion or production of carbon

monoxide may result causing property damage, personal injury or loss of

life. The qualified service agency is responsible for the proper installation

of this kit. The installation is not proper and complete until the operation

of the converted appliance is checked as specified in the manufacturer’s

instructions supplied with the kit.The qualified service agency performing

this installation assumes responsibility for this conversion.

AVERTISSEMENT

Cette trousse de conversion doit être installée par un technicien agréé,

selon les instructions du fabricant et selon toutes les exigences et tous les

codes pertinents de l’autorité compétente. Assurez-vous de bien suivre

les instructions dans cette notice pour réduire au minimum le risque

d’incendie, d’explosion ou la production de monoxyde de carbone pouvant

causer des dommages matériels, des blessures ou la mort. Le tecnicien

agréé est responsable de l’installation de cette trousse. L’installation n’est

pas adéquate ni complète tant que le bon fonctionnement de l’appareil

converti n’a pas été vérifié selon les instructions du fabricant fournies avec

la trousse. Le fournisseur de service qualifié ayant réalisé l'installation

assume les responsabilités liées à la conversion.

Advertising